Comparisons in finite element analysis of minimally invasive, locking, and non-locking plates systems used in treating calcaneal fractures of Sanders type II and type III.

作者信息

He Kai, Fu Su, Liu Song, Wang Zhifa, Jin Dan

机构信息

Department of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, China; Department of Orthopaedics, The Ordos Center Hospital, The Ordos Clinic Medical College, Inner Mongolia Medical University, Ordos, Inner Mongolia 017000, China.

Department of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, China.

出版信息

Chin Med J (Engl). 2014;127(22):3894-901.

Abstract

BACKGROUND

Calcaneal fractures are relatively common but complex, while the treatment of these fractures is still controversial. The objective of this study was to compare the biomechanical stability of minimally invasive, locking, and non-locking plating systems used for fixing Sanders type II and type III calcaneal fractures. Finite element analysis was used for comparing the three types of plating systems. This study helped in guiding the clinical management of calcaneal fractures.

METHODS

The CT data acquired from a volunteer was used to construct a finite element model of calcaneus. The fracture lines were made according to Sanders type II (A, B, C) and type III (AB, AC, BC) and six calcaneal fractures models were constructed accordingly. Three fixation methods used in clinical treatment were simulated by design tools (minimally invasive plating with percutaneous screws, Y-size non-locking plating, and locking plating) and then fixed to these fracture models with the help of clinical principles. The single minimally invasive plating fixation was also tested to compare the function of percutaneous screws. Then, the neutral force was applied on established methods. The displacement and presses distribution condition in various plating models were analyzed and compared.

RESULTS

The levels of displacement and compressive press on the bone around fixation or strains on plating were within the physiological limit, indicating that the three methods were suitable for application. Compared with the locked and unlocked plates, the minimally invasive plating caused a relatively lower displacement without the high stress in bone or fixation. The minimum stress in fixation was observed in locking plate as the distribution of stress was concentrated in the anterior part of locking plate.

CONCLUSIONS

The minimally invasive plating method could be a better alternative method in treating Sanders type II and type III calcaneal fractures. The observed stiffness of locking plate was not obviously stronger than unlocked plate.

摘要

背景

跟骨骨折相对常见但较为复杂,而此类骨折的治疗仍存在争议。本研究的目的是比较用于固定Sanders II型和III型跟骨骨折的微创、锁定和非锁定钢板系统的生物力学稳定性。采用有限元分析来比较这三种钢板系统。本研究有助于指导跟骨骨折的临床治疗。

方法

使用从一名志愿者获取的CT数据构建跟骨的有限元模型。根据Sanders II型(A、B、C)和III型(AB、AC、BC)制作骨折线,并据此构建六个跟骨骨折模型。通过设计工具模拟临床治疗中使用的三种固定方法(经皮螺钉微创钢板固定、Y型非锁定钢板固定和锁定钢板固定),然后借助临床原则将其固定到这些骨折模型上。还测试了单一的微创钢板固定以比较经皮螺钉的功能。然后,对既定方法施加中性力。分析并比较各种钢板模型中的位移和压力分布情况。

结果

固定周围骨骼上的位移和压缩压力水平或钢板上的应变均在生理限度内,表明这三种方法均适用于临床。与锁定钢板和非锁定钢板相比,微创钢板固定导致的位移相对较低,且骨骼或固定部位无高应力。锁定钢板固定中的应力最小,因为应力分布集中在锁定钢板的前部。

结论

微创钢板固定方法可能是治疗Sanders II型和III型跟骨骨折的更好替代方法。观察到锁定钢板的刚度并不明显强于非锁定钢板。