Suppr超能文献

使用傅里叶变换红外光谱法测定奶牛血清免疫球蛋白G:一种无试剂方法。

Measurement of serum immunoglobulin G in dairy cattle using Fourier-transform infrared spectroscopy: a reagent free approach.

作者信息

Elsohaby Ibrahim, Riley Christopher B, Hou Siyuan, McClure J Trenton, Shaw R Anthony, Keefe Gregory P

机构信息

Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, 550 University Avenue, Charlottetown, Prince Edward Island C1A 4P3, Canada; Infectious Diseases, Department of Animal Medicine, Faculty of Veterinary Medicine, Zagazig University, Zagazig City 44511, Sharkia Province, Egypt.

Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, 550 University Avenue, Charlottetown, Prince Edward Island C1A 4P3, Canada; Institute of Veterinary, Animal and Biomedical Sciences, Massey University, Palmerston North 4442, New Zealand.

出版信息

Vet J. 2014 Dec;202(3):510-5. doi: 10.1016/j.tvjl.2014.09.014. Epub 2014 Sep 20.

Abstract

Simple, rapid and cost-effective methods are sought for measuring immunoglobulin G (IgG) concentrations in bovine serum, which can be applied for diagnosis of failure of transfer of passive immunity (FTPI). The aim of the present study was to investigate the potential use of Fourier-transform infrared (FTIR) spectroscopy, with partial least squares (PLS) regression, to measure IgG concentrations in bovine serum. Serum samples collected from calves and adult cows were tested in parallel by radial immunodiffusion (RID) assay and FTIR spectroscopy. The sample IgG concentrations obtained by the RID method were linked to pre-processed spectra and divided into two sets: a combined set and a test set. The combined set was used for building a calibration model, while the test set was used to assess the predictive ability of the calibration model, resulting in a root mean squared error of prediction (RMSEP) of 307.5 mg/dL. The concordance correlations between the IgG measured by RID and predicted by FTIR spectroscopy were 0.96 and 0.93 for the combined and test data sets, respectively. Analysis of the data using the Bland-Altman method did not show any evidence of systematic bias between FTIR spectroscopy and RID methods for measurement of IgG. The clinical applicability of FTIR spectroscopy for diagnosis of FTPI was evaluated using the entire data set and showed a sensitivity of 0.91 and specificity of 0.96, using RID as the reference standard. The FTIR spectroscopy method, described in the present study, demonstrates potential as a rapid and reagent-free tool for quantification of IgG in bovine serum, as an aid to diagnosis of FTPI in calves.

摘要

人们正在寻找简单、快速且经济高效的方法来测量牛血清中的免疫球蛋白G(IgG)浓度,该方法可用于诊断被动免疫转移失败(FTPI)。本研究的目的是研究傅里叶变换红外(FTIR)光谱结合偏最小二乘法(PLS)回归测量牛血清中IgG浓度的潜在用途。从犊牛和成年母牛采集的血清样本通过放射免疫扩散(RID)测定和FTIR光谱进行平行测试。通过RID方法获得的样本IgG浓度与预处理光谱相关联,并分为两组:组合集和测试集。组合集用于建立校准模型,而测试集用于评估校准模型的预测能力,预测均方根误差(RMSEP)为307.5mg/dL。对于组合数据集和测试数据集,RID测量的IgG与FTIR光谱预测的IgG之间的一致性相关性分别为0.96和0.93。使用Bland-Altman方法对数据进行分析,未显示FTIR光谱法和RID法在测量IgG方面存在系统偏差的任何证据。以RID作为参考标准,使用整个数据集评估FTIR光谱法对FTPI诊断的临床适用性,结果显示灵敏度为0.91,特异性为0.96。本研究中描述的FTIR光谱法显示出作为一种快速且无需试剂的工具来定量牛血清中IgG的潜力,有助于诊断犊牛的FTPI。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验