Suppr超能文献

BP180 NC16a和BP230-C3 ELISA在大疱性类天疱疮患者血清和唾液中的诊断准确性

Diagnostic accuracy of BP180 NC16a and BP230-C3 ELISA in serum and saliva of patients with bullous pemphigoid.

作者信息

Esmaili N, Mortazavi H, Kamyab-Hesari K, Aghazadeh N, Daneshpazhooh M, Khani S, Chams-Davatchi C

机构信息

Autoimmune Bullous Diseases Research Center, Department of Dermatology, Tehran University of Medical Sciences, Tehran, Iran.

出版信息

Clin Exp Dermatol. 2015 Apr;40(3):324-30. doi: 10.1111/ced.12510. Epub 2014 Dec 5.

Abstract

BACKGROUND

Bullous pemphigoid (BP) is a subepidermal blistering disease, characterized by autoantibodies directed against BP180 and BP230. Collecting saliva is an easy and painless way of obtaining biological samples, and can be used for diagnosis of autoimmune diseases.

AIM

To compare the diagnostic accuracy of serum and salivary BP180-NC16a and BP230-C3 in the initial diagnosis of BP.

METHODS

We assessed 50 patients newly diagnosed with BP and 50 healthy controls. The diagnosis of BP was confirmed based on clinical, histopathological and immunofluorescence findings. Serum and saliva samples were collected from both groups, and BP180 and BP230 titres were assessed using commercially available ELISA kits.

RESULTS

Using serum, the sensitivity of the serum BP180 and BP230 ELISA assays was 88% and 48%, respectively, and the specificity of both was 96%. Using saliva with the cutoff value proposed by the manufacturer, sensitivity was 56.2% and 14.6%, and specificity was 98% and 100%, respectively. Using the best calculated cutoff for saliva, sensitivity increased to 87.5% and 77.1%, and specificity to 96% and 62%, respectively. There was a significant correlation between serum and saliva BP180 levels and the severity of skin disease. Both serum and saliva BP230 levels were significantly higher in patients with mucosal involvement.

CONCLUSION

Serum BP180 NC16a ELISA is a sensitive and specific test for the initial diagnosis of BP, whereas serum BP230-C3 ELISA is highly specific, but less sensitive. Saliva may be a noninvasive and convenient alternative for use in the BP180 NC16a ELISA to diagnose BP.

摘要

背景

大疱性类天疱疮(BP)是一种表皮下疱病,其特征为针对BP180和BP230的自身抗体。收集唾液是获取生物样本的一种简便且无痛的方法,可用于自身免疫性疾病的诊断。

目的

比较血清和唾液中BP180-NC16a及BP230-C3在BP初诊时的诊断准确性。

方法

我们评估了50例新诊断为BP的患者和50名健康对照者。BP的诊断基于临床、组织病理学和免疫荧光检查结果得以证实。从两组中收集血清和唾液样本,并使用市售ELISA试剂盒评估BP180和BP230滴度。

结果

使用血清时,血清BP180和BP230 ELISA检测的敏感性分别为88%和48%,两者的特异性均为96%。使用制造商建议的唾液临界值时,敏感性分别为56.2%和14.6%,特异性分别为98%和100%。使用唾液的最佳计算临界值时,敏感性分别增至87.5%和77.1%,特异性分别增至96%和62%。血清和唾液BP180水平与皮肤病严重程度之间存在显著相关性。黏膜受累患者的血清和唾液BP230水平均显著更高。

结论

血清BP180 NC16a ELISA是BP初诊的一种敏感且特异的检测方法,而血清BP230-C3 ELISA具有高度特异性,但敏感性较低。唾液可能是用于BP180 NC16a ELISA诊断BP的一种非侵入性且便捷的替代方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验