Suppr超能文献

Oximetry in cells and tissues using a nitroxide-liposome system.

作者信息

Chan H C, Glockner J F, Swartz H M

机构信息

College of Medicine, Department of Medicine, University of Illinois, Urbana 61801.

出版信息

Biochim Biophys Acta. 1989 Nov 20;1014(2):141-4. doi: 10.1016/0167-4889(89)90026-8.

Abstract

In order to avoid the complication of reduction of nitroxides in biological media during oxygen measurements, liposomes containing a water-soluble nitroxide, 2,2,6,6-tetramethyl-piperidine-N-oxyl-4-trimethylammonium (Cat1), were used in studies of oxygen consumption by thymus-bone-marrow cells. The superhyperfine structure of Cat1 contained in liposomes was found to be sensitive to oxygen concentration in a fashion similar to that of free Cat1. Measurements of cellular respiration using Cat1 contained in liposomes agreed well with the results obtained using free Cat1. Using this nitroxide-liposome system, the respiration of liver slices was measured successfully, whereas such measurements using free cat1 were complicated by rapid reduction of the nitroxide. This nitroxide-liposome system also could be used in conjunction with a membrane permeable nitroxide and an extracellular broadening agent to measure intracellular and extracellular oxygen concentrations simultaneously.