Lasarte-Aragonés Guillermo, Lucena Rafael, Cárdenas Soledad, Valcárcel Miguel
Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Campus de Rabanales, University of Córdoba, Córdoba, Spain.
J Sep Sci. 2015 Mar;38(6):990-5. doi: 10.1002/jssc.201401224. Epub 2015 Feb 13.
A homogeneous liquid-liquid microextraction alternative, based on the use of switchable hydrophilicity solvents, is presented. The extraction technique makes use of 125 μL of a water-immiscible solvent (N,N-dimethylcyclohexylamine) that can be solubilized in the aqueous phase in 1:1 ratio using CO2 as a reagent. After the extraction, phase separation is induced by the addition of sodium hydroxide that produces a change on the ionization state of the amine, and centrifugation was not necessary. The extraction technique has been optimized and characterized using the determination of triazine herbicides by gas chromatography with mass spectrometry in water samples. The presence of metallic ions in environmental waters as interferents is easily avoided by the addition of ethylenediaminetetraacetic acid before the microextraction procedure. The proposed method allows the determination of the target analytes at the low microgram per liter range with good precision (relative standard deviation lower than 12.5%).
本文提出了一种基于可切换亲水性溶剂的均相液-液微萃取方法。该萃取技术使用125 μL与水不混溶的溶剂(N,N-二甲基环己胺),该溶剂可使用二氧化碳作为试剂以1:1的比例溶解于水相中。萃取后,通过加入氢氧化钠诱导相分离,氢氧化钠会使胺的电离状态发生变化,无需离心。该萃取技术已通过气相色谱-质谱法测定水样中的三嗪类除草剂进行了优化和表征。在微萃取程序之前加入乙二胺四乙酸,可轻松避免环境水体中金属离子作为干扰物的存在。该方法能够在低微克每升范围内测定目标分析物,精密度良好(相对标准偏差低于12.5%)。