Ateş Ahmet Hakan, Sunman Hamza, Aytemir Kudret, Yorgun Hikmet, Canpolat Uğur, Topcuoğlu Mehmet Akif, Karlı Oğuz Kader, Şahiner Levent, Kaya Ergün Barış, Tokgözoğlu Lale, Kabakçı Giray, Oto Ali
Department of Cardiology, Samsun Training and Research Hospital, Samsun, Turkey.
Department of Cardiology, Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey.
Turk Kardiyol Dern Ars. 2015 Jan;43(1):38-46. doi: 10.5543/tkda.2015.68148.
In this study, we aimed to evaluate the effect of percutaneous closure of patent foramen ovale (PFO) on the recurrence of stroke and new cardiac arrhythmia using magnetic resonance imaging (MRI) and Holter monitoring.
Patients with PFO had >1 previous stroke or transient ischemic attack documented with MRI in the first event. PFO with right to left shunt was detected by transesophageal echocardiography (TEE) and transcranial Doppler ultrasound. MRI examinations were performed on patients before and one year after PFO closure was applied. A twenty-four hour Holter monitoring was performed in all patients within 1 month before and 6 months after the procedure.
Percutaneous PFO closure was performed on 47 patients (25 female, mean age: 38.7 years) who had cerebral ischemic events detected by MRI. A year after the procedure, TEE showed that there was no residual interatrial right-to-left shunting. After a 14 month follow-up, no new cerebrovascular event and no new lesion on MRI were recorded. The incidence of arrhythmia did not increase significantly after the procedure on Holter monitoring (p=0.917).
One-year clinical and MRI follow-up study of patients with cerebral ischemic events and percutaneous closure of PFO showed no recurrent event and no significant complication associated with the procedure. In addition, Holter monitorization demonstrated that the procedure did not increase the incidence of arrhythmias compared with pre-procedural monitoring.
在本研究中,我们旨在利用磁共振成像(MRI)和动态心电图监测,评估经皮闭合卵圆孔未闭(PFO)对中风复发和新发心律失常的影响。
患有PFO的患者在首次事件中经MRI记录有1次以上中风或短暂性脑缺血发作。通过经食管超声心动图(TEE)和经颅多普勒超声检测存在右向左分流的PFO。在应用PFO闭合术前及术后1年对患者进行MRI检查。在手术前1个月内及术后6个月内对所有患者进行24小时动态心电图监测。
对47例经MRI检测出脑缺血事件的患者(25例女性,平均年龄:38.7岁)进行了经皮PFO闭合术。术后1年,TEE显示心房水平无残余右向左分流。经过14个月的随访,未记录到新的脑血管事件,MRI上也未出现新病灶。动态心电图监测显示术后心律失常发生率无显著增加(p = 0.917)。
对脑缺血事件患者进行经皮PFO闭合术的1年临床及MRI随访研究显示,无复发事件,且该手术未出现显著并发症。此外,动态心电图监测表明,与术前监测相比,该手术未增加心律失常的发生率。