Mortazavi Hossein, Khatami Alireza, Seyedin Zahra, Vasheghani Farahani Iman, Daneshpazhooh Maryam
Autoimmune Bullous Diseases Research Center, Tehran University of Medical Sciences, Tehran 1199663911, Iran ; Department of Dermatology, Razi Hospital, Tehran University of Medical Sciences, Vahdat Islamic Square, Tehran 1199663911, Iran.
Center for Research and Training in Skin Diseases and Leprosy, Tehran University of Medical Sciences, Tehran 1416613675, Iran.
Biomed Res Int. 2015;2015:698310. doi: 10.1155/2015/698310. Epub 2015 Jan 22.
Serum desmoglein enzyme-linked immunosorbent assay (ELISA) is used for the diagnosis and monitoring of pemphigus diseases.
To compare the diagnostic accuracy of salivary antidesmoglein (Dsg) 1 and 3 ELISA in the diagnosis of pemphigus vulgaris (PV) patients with that of serum desmogleins ELISA.
Eighty-six untreated PV patients and 180 age- and sex-matched PV-free controls were recruited in this case-control study. PV was diagnosed based on clinical, histopathological, and direct immunofluorescence findings. After processing, serum and salivary anti-Dsg 1 and 3 were measured by the ELISA method using Euroimmun kit (Lübeck, Germany).
Using the cut-off point of 20 relative units (RU)/mL, the serum anti-Dsg 1 and 3 ELISA were positive in 62 (72.1%) and 83 (96.5%) patients, respectively, and the salivary anti-Dsg 1 and 3 ELISA were positive in 31 (36.1%) and 63 (73.3%) patients, respectively. The specificity of salivary anti-Dsg 1 and anti-Dsg 3 were both 98.9%. Optimal cut-off values of 7.7 and 13.4 RU/mL were determined for the salivary anti-Dsg 1 and anti-Dsg 3 ELISA, respectively.
Salivary anti-Dsg 1 and 3 ELISA with high specificities (98.9%) could be suggested as safe and noninvasive methods for the diagnosis of PV when obtaining a blood sample is difficult.
血清桥粒芯糖蛋白酶联免疫吸附测定(ELISA)用于天疱疮疾病的诊断和监测。
比较唾液抗桥粒芯糖蛋白(Dsg)1和3 ELISA对寻常型天疱疮(PV)患者的诊断准确性与血清桥粒芯糖蛋白ELISA的诊断准确性。
在这项病例对照研究中招募了86例未经治疗的PV患者和180例年龄及性别匹配的无PV对照者。PV根据临床、组织病理学和直接免疫荧光检查结果进行诊断。处理后,使用德国吕贝克的欧蒙试剂盒通过ELISA法检测血清和唾液中的抗Dsg 1和3。
以20相对单位(RU)/mL为临界值,血清抗Dsg 1和3 ELISA分别在62例(72.1%)和83例(96.5%)患者中呈阳性,唾液抗Dsg 1和3 ELISA分别在31例(36.1%)和63例(73.3%)患者中呈阳性。唾液抗Dsg 1和抗Dsg 3的特异性均为98.9%。唾液抗Dsg 1和抗Dsg 3 ELISA的最佳临界值分别确定为7.7和13.4 RU/mL。
唾液抗Dsg 1和3 ELISA具有高特异性(98.9%),在难以采集血样时可作为诊断PV的安全、非侵入性方法。