Venter Jan A, Pelouskova Martina, Schallhorn Steven C, Collins Barrie M
From Optical Express, London, United Kingdom.
From Optical Express, London, United Kingdom.
J Cataract Refract Surg. 2015 Mar;41(3):541-7. doi: 10.1016/j.jcrs.2014.06.037.
To evaluate the effect of implantation of iris-fixated phakic intraocular lenses (pIOLs) (Artisan) in adult amblyopic eyes.
Optical Express, London, United Kingdom.
Retrospective case series.
The study analyzed data from 5 years of follow-up of amblyopic eyes that were implanted with iris-fixated pIOLs and had a preoperative corrected distance visual acuity (CDVA) of 6/15 or worse. Visual acuity, refraction, endothelial cell count, and complications were assessed.
Data for 103 eyes were analyzed as 2 groups. Group 1 comprised 82 eyes with myopia or myopic astigmatism, and Group 2 contained 21 eyes with hyperopia or hyperopic astigmatism. The mean preoperative sphere in Group 1 was -13.42 diopters (D) ± 5.62 (SD) with a mean cylinder of -2.35 ± 1.75 D. In Group 2, the mean sphere and cylinder were +6.77 ± 1.91 D and -2.63 ± 2.43 D, respectively. The mean CDVA improved from 0.51 ± 0.15 logMAR to 0.34 ± 0.16 logMAR (P<.001) in Group 1 and from 0.54 ± 0.17 logMAR to 0.46 ± 0.14 logMAR in Group 2 (P<.005). The safety index was 1.48 in Group 1 and 1.19 in Group 2. The efficacy index was 1.21 in Group 1 and 1.00 in Group 2. The mean gain in CDVA was statistically significantly greater in Group 1 (0.17 ± 0.14 logMAR) than in Group 2 (0.08 ± 0.11 logMAR). Two or more lines of CDVA were gained by 48.8% of eyes in Group 1 and by 19.0% of eyes in Group 2.
The iris-fixated pIOL was a safe and effective option for improving visual acuity in adult amblyopic eyes.
Dr. Schallhorn is a consultant to Abbott Medical Optics, Inc. No other author has a financial or proprietary interest in any material or method mentioned.
评估虹膜固定型有晶状体眼人工晶状体(pIOL)(Artisan)植入成年弱视眼的效果。
英国伦敦的Optical Express。
回顾性病例系列。
该研究分析了5年随访期内植入虹膜固定型pIOL且术前矫正远视力(CDVA)为6/15或更差的弱视眼的数据。评估了视力、屈光、内皮细胞计数和并发症。
103只眼的数据分为两组进行分析。第1组包括82只近视或近视散光眼,第2组包含21只远视或远视散光眼。第1组术前平均球镜度数为-13.42屈光度(D)±5.62(标准差),平均柱镜度数为-2.35±1.75D。第2组的平均球镜和柱镜度数分别为+6.77±1.91D和-2.63±2.43D。第1组平均CDVA从0.51±0.15对数最小分辨角(logMAR)提高到0.34±0.16 logMAR(P<0.001),第2组从0.54±0.17 logMAR提高到0.46±0.14 logMAR(P<0.005)。第1组的安全指数为1.48,第2组为1.19。第1组的疗效指数为1.21,第2组为1.00。第1组CDVA的平均提高幅度(0.17±0.14 logMAR)在统计学上显著大于第2组(0.08±0.11 logMAR)。第1组48.8%的眼CDVA提高了两行或更多,第2组为19.0%。
虹膜固定型pIOL是提高成年弱视眼视力的一种安全有效的选择。
Schallhorn博士是雅培医疗光学公司的顾问。其他作者对文中提及的任何材料或方法均无财务或专利权益。