An analytical method was developed for the simultaneous determination of 32 pesticides including organophosphorus, organochlorine, pyrethroid and carbamate pesticides in fruits and vegetables using gas chromatography-mass spectrometry (GC-MS). The sample was extracted with acetonitrile, and the organic layer was cleaned up with ENVI-Carb and LC-NH2 cartridges. A large volume of 20 µL purified solution was injected into the GC system using programmable temperature vaporizer (PTV). The mass spectrometric detection was operated with full scan mode. The automated mass spectral deconvolution and identification system (AMDIS) and an isotopic internal standard were used for the qualitative and quantitative determination of the 32 pesticides, respectively. The conditions for PTV-large volume injection were studied. Furthermore, the selectivity and durability of the method were also assessed. Under the optimized conditions, the experimental results showed that all the linearities were good within their test ranges, with correlation coefficients more than 0. 995, and the method detection limits of the pesticides were 2.0-5.0 µg/kg. The spiked recoveries (n=6) at three levels in the 0. 010 - 0. 50 mg/kg using spinach, snap bean and cucumber samples as blank matrices were in the range of 65. 2% - 120. 3% with the relative standard deviations (RSDs) varying from 4. 1% to 22. 3%, showing good accuracy of the method. The advantages of the proposed method include high throughput, high sensitivity, reliability, robustness, and the ability to meet the demand of multi-residue pesticide analysis in fruits and vegetables.
建立了一种使用气相色谱 - 质谱联用仪(GC - MS)同时测定水果和蔬菜中32种农药(包括有机磷、有机氯、拟除虫菊酯和氨基甲酸酯类农药)的分析方法。样品用乙腈提取,有机层用ENVI - Carb和LC - NH₂ 小柱净化。使用程序升温汽化器(PTV)将20 μL大量的净化溶液注入GC系统。质谱检测采用全扫描模式。分别使用自动质谱解卷积和鉴定系统(AMDIS)和同位素内标对32种农药进行定性和定量测定。研究了PTV - 大体积进样的条件。此外,还评估了该方法的选择性和耐用性。在优化条件下,实验结果表明,所有农药在其测试范围内线性良好,相关系数大于0.995,方法检出限为2.0 - 5.0 μg/kg。以菠菜、四季豆和黄瓜样品为空白基质,在0.010 - 0.50 mg/kg三个添加水平下的加标回收率(n = 6)在65.2% - 120.3%范围内,相对标准偏差(RSD)为4.1% - 22.3%,表明该方法具有良好的准确性。该方法的优点包括高通量、高灵敏度、可靠性、稳健性以及能够满足水果和蔬菜中多残留农药分析的需求。