Selvadurai Paul A, Glaser Steven D
University of California, Berkeley, CA 94720, USA.
Sensors (Basel). 2015 Apr 27;15(5):9791-814. doi: 10.3390/s150509791.
A pressure-sensitive film was used to characterize the asperity contacts along a polymethyl methacrylate (PMMA) interface in the laboratory. The film has structural health monitoring (SHM) applications for flanges and other precision fittings and train rail condition monitoring. To calibrate the film, simple spherical indentation tests were performed and validated against a finite element model (FEM) to compare normal stress profiles. Experimental measurements of the normal stress profiles were within -7.7% to 6.6% of the numerical calculations between 12 and 50 MPa asperity normal stress. The film also possessed the capability of quantifying surface roughness, an important parameter when examining wear and attrition in SHM applications. A high definition video camera supplied data for photometric analysis (i.e., the measure of visible light) of asperities along the PMMA-PMMA interface in a direct shear configuration, taking advantage of the transparent nature of the sample material. Normal stress over individual asperities, calculated with the pressure-sensitive film, was compared to the light intensity transmitted through the interface. We found that the luminous intensity transmitted through individual asperities linearly increased 0.05643 ± 0.0012 candelas for an increase of 1 MPa in normal stress between normal stresses ranging from 23 to 33 MPa.
在实验室中,使用了一种压敏薄膜来表征沿聚甲基丙烯酸甲酯(PMMA)界面的粗糙接触。该薄膜可用于法兰和其他精密配件的结构健康监测(SHM)以及铁轨状态监测。为了校准该薄膜,进行了简单的球形压痕试验,并与有限元模型(FEM)进行了验证,以比较法向应力分布。在粗糙度法向应力为12至50MPa之间时,法向应力分布的实验测量值与数值计算值的偏差在-7.7%至6.6%之间。该薄膜还具备量化表面粗糙度的能力,这是在SHM应用中检查磨损时的一个重要参数。利用样品材料的透明特性,一台高清摄像机为沿PMMA - PMMA界面在直接剪切配置下的粗糙表面的光度分析(即可见光测量)提供数据。用压敏薄膜计算出的各个粗糙表面上的法向应力与透过界面的光强进行了比较。我们发现,在法向应力范围为23至33MPa之间,法向应力每增加1MPa,透过各个粗糙表面的发光强度线性增加0.05643±0.0012坎德拉。