Sultan Sherif, Kavanagh Edel P, Bonneau Michel, Kang Chantal, Alves Antoine, Hynes Niamh M
Department of Vascular and Endovascular Surgery, Western Vascular Institute, University Hospital Galway, Galway, Ireland Department of Vascular and Endovascular Surgery, Galway Clinic, Doughiska, Galway, Ireland
Department of Vascular and Endovascular Surgery, Galway Clinic, Doughiska, Galway, Ireland.
Vascular. 2016 Feb;24(1):78-87. doi: 10.1177/1708538115585073. Epub 2015 May 7.
The multilayer flow modulator (MFM; Cardiatis, Isnes, Belgium) is a self-expandable mesh of braided cobalt alloy wires, used for treatment of aortic and peripheral aneurysms. To further improve our understanding of this novel technology, the endothelialization kinetics of the MFM was investigated and compared with those of two marketed single-layer stents. Five porcine animal models were used in which a total of 19 stents were implanted in the iliac and carotid arteries between one and five weeks before sacrifice. All 19 stents were successfully delivered. For all devices, nonsignificant signs of inflammation or thrombosis were noted, and there was no evidence of local intolerance. The MFM developed a thin layer of endothelial cells earlier and was associated with less neointimal development than the two single-layer stents. A differing phenomenon of integration was also revealed and hypothesized as endothelialization from adhesion of circulating endothelial progenitor cells, as well as adhesion from the arterial wall, and also by the differences in trauma exposed to the arterial wall.
多层血流调节器(MFM;比利时伊斯内斯的Cardiatis公司)是一种由编织钴合金丝制成的可自膨胀网状物,用于治疗主动脉瘤和外周动脉瘤。为了进一步加深我们对这项新技术的理解,研究了MFM的内皮化动力学,并与两种市售单层支架的内皮化动力学进行了比较。使用了5只猪动物模型,在处死前1至5周,共在髂动脉和颈动脉中植入了19个支架。所有19个支架均成功植入。对于所有器械,均未观察到明显的炎症或血栓形成迹象,也没有局部不耐受的证据。与两个单层支架相比,MFM更早地形成了一层薄的内皮细胞,并且内膜增生较少。还揭示了一种不同的整合现象,并推测其为循环内皮祖细胞黏附导致的内皮化,以及动脉壁的黏附,同时也与动脉壁所受创伤的差异有关。