Suppr超能文献

Specificity and sensitivity of visual evoked potentials in the diagnosis of schizophrenia: rethinking VEPs.

作者信息

González-Hernández J A, Pita-Alcorta C, Wolters C H, Padrón A, Finalé A, Galán-García L, Marot M, Lencer R

机构信息

Department of Neurophysiology, "Hermanos-Ameijeiras" Hospital, University of Medical Science of Havana, Cuba; Department of Psychiatry, "Hermanos-Ameijeiras" Hospital, University of Medical Science of Havana, Cuba; Department of Psychiatry and Psychotherapy, University of Münster, Germany.

Department of Psychiatry, "Manuel Fajardo" Hospital, University of Medical Science of Havana, Cuba.

出版信息

Schizophr Res. 2015 Aug;166(1-3):231-4. doi: 10.1016/j.schres.2015.05.007. Epub 2015 May 23.

Abstract

Alterations of the visual evoked potential (VEP) component P1 at the occipital region represent the most extended functional references of early visual dysfunctions in schizophrenia (SZ). However, P1 deficits are not reliable enough to be accepted as standard susceptibility markers for use in clinical psychiatry. We have previously reported a novel approach combining a standard checkerboard pattern-reversal stimulus, spectral resolution VEP, source detection techniques and statistical procedures which allowed the correct classification of all patients as SZ compared to controls. Here, we applied the same statistical approach but to a single surface VEP - in contrast to the complex EEG source analyses in our previous report. P1 and N1 amplitude differences among spectral resolution VEPs from a POz-F3 bipolar montage were computed for each component. The resulting F-values were then Z-transformed. Individual comparisons of each component of P1 and N1 showed that in 72% of patients, their individual Z-score deviated from the normal distribution of controls for at least one of the two components. Crossvalidation against the distribution in the SZ-group improved the detection rate to 93%. In all, six patients were misclassified. Clinical validation yielded striking positive (78.13%) and negative (92.69%) predictive values. The here presented procedure offers a potential clinical screening method for increased susceptibility to SZ which should then be followed by high density electrode array and source detection analyses. The most important aspect of this work is represented by the fact that this diagnostic technique is low-cost and involves equipment that is feasible to use in typical community clinics.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验