Accurate torque application and determination of the applied torque during surgical and prosthetic treatment is important to reduce complications. A study was performed to determine and compare the accuracy of manual wrenches, which are available in different designs with a large range of preset torques.
Thirteen different wrench systems with a variety of preset torques ranging from 10 to 75 Ncm were evaluated. Three different designs were available, with a spring-in-coil or toggle design as an active mechanism or a beam as a passive mechanism, to select the preset torque. To provide a clinically relevant analysis, a total of 1,170 torque measurements in the range of 10 to 45 Ncm were made in vitro using an electronic torque measurement device.
The absolute deviations in Ncm and percent deviations across all wrenches were small, with a mean of -0.24 ± 2.15 Ncm and -0.84% ± 11.72% as a shortfall relative to the preset value. The greatest overage was 8.2 Ncm (82.5%), and the greatest shortfall was 8.47 Ncm (46%). However, extreme values were rare, with 95th-percentile values of -1.5% (lower value) and -0.16% (upper value). A comparison with respect to wrench design revealed significantly higher deviations for coil and toggle-style wrenches than for beam wrenches.
Beam wrenches were associated with a lower risk of rare extreme values thanks to their passive mechanism of achieving the selected preset torque, which minimizes the risk of harming screw connections.
在外科手术和修复治疗过程中,准确施加扭矩并确定所施加的扭矩对于减少并发症很重要。本研究旨在确定并比较手动扳手的准确性,这些扳手有不同的设计,预设扭矩范围广泛。
评估了13种不同的扳手系统,其预设扭矩范围为10至75 Ncm。有三种不同的设计可供选择,以螺旋弹簧或肘节设计作为主动机构,或以梁作为被动机构来选择预设扭矩。为了进行临床相关分析,使用电子扭矩测量装置在体外进行了总共1170次10至45 Ncm范围内的扭矩测量。
所有扳手的Ncm绝对偏差和百分比偏差都很小,相对于预设值的平均短缺为-0.24±2.15 Ncm和-0.84%±11.72%。最大超量为8.2 Ncm(82.5%),最大短缺为8.47 Ncm(46%)。然而,极端值很少见,第95百分位数的值为-1.5%(较低值)和-0.16%(较高值)。关于扳手设计的比较显示,螺旋弹簧和肘节式扳手的偏差明显高于梁式扳手。
梁式扳手因其实现选定预设扭矩的被动机制,与罕见极端值的风险较低相关,这将损害螺丝连接的风险降至最低。