产后腹直肌分离女性的超声成像:组内两次检测间的可靠性。
Ultrasound Imaging in Postpartum Women With Diastasis Recti: Intrarater Between-Session Reliability.
机构信息
School of Rehabilitation Therapy, Queen's University, Kingston, Ontario, Canada.
出版信息
J Orthop Sports Phys Ther. 2015 Sep;45(9):713-8. doi: 10.2519/jospt.2015.5879. Epub 2015 Jul 10.
STUDY DESIGN
Clinimetrics.
OBJECTIVES
To investigate the intrarater between-session reliability of inter-rectus distance (IRD) measurement using ultrasound imaging in postpartum women with diastasis recti.
BACKGROUND
Diastasis recti, a separation of the rectus abdominis muscles at the linea alba, occurs as a result of pregnancy and is characterized by increased IRD. The measurement of IRD in this population is of interest to determine changes in diastasis recti severity over time, or in response to treatment. Ultrasound imaging has been proposed as a useful tool to measure IRD in women with diastasis recti; however, the consistency of IRD measurement in this population using ultrasound imaging has, to our knowledge, never been investigated.
METHODS
Ultrasound imaging was used to measure IRD in 20 women with diastasis recti on 2 different occasions. On each testing occasion, images were acquired at 4 locations along the linea alba while participants remained relaxed and while they performed a head lift to activate the rectus abdominis muscles. Reliability statistics included intraclass correlation coefficients, Bland-Altman analyses, minimum clinically important difference, and standard error of the measurement.
RESULTS
Between-session reliability of IRD measurement was high, particularly when measuring IRD at or above the umbilicus, as indicated by intraclass correlation coefficients greater than 0.90 and low standard error of the measurement and minimum clinically important difference values (below 0.17 cm and 0.46 cm, respectively). Reliability coefficients were poorer when measuring IRD below the umbilicus.
CONCLUSION
When performed by an experienced investigator, ultrasound imaging is a reliable tool by which to measure IRD in postpartum women who have diastasis recti.
研究设计
临床计量学。
目的
研究产后腹直肌分离女性使用超声成像测量腹直肌间距离(IRD)的组内间可靠性。
背景
腹直肌分离是腹白线处腹直肌的分离,是妊娠的结果,其特征是 IRD 增加。测量该人群的 IRD 有助于确定腹直肌分离严重程度随时间的变化,或对治疗的反应。超声成像已被提议作为一种有用的工具来测量腹直肌分离的女性的 IRD;然而,据我们所知,超声成像在该人群中测量 IRD 的一致性从未被研究过。
方法
使用超声成像在 20 名腹直肌分离的女性的 2 个不同场合测量 IRD。在每个测试场合,在腹白线的 4 个位置获取图像,同时参与者保持放松状态,同时进行头部抬起以激活腹直肌。可靠性统计包括组内相关系数、Bland-Altman 分析、最小临床重要差异和测量标准误差。
结果
IRD 测量的组内间可靠性较高,尤其是在脐部或以上测量时,组内相关系数大于 0.90,测量标准误差和最小临床重要差异值较低(分别低于 0.17cm 和 0.46cm)。当在脐部以下测量 IRD 时,可靠性系数较差。
结论
当由经验丰富的研究人员进行时,超声成像可作为一种可靠的工具,用于测量产后腹直肌分离的女性的 IRD。