Suppr超能文献

根管治疗后磨牙牙尖应变和残余应力的修复方案影响。

Effect of Restorative Protocol on Cuspal Strain and Residual Stress in Endodontically Treated Molars.

出版信息

Oper Dent. 2016 Jan-Feb;41(1):23-33. doi: 10.2341/14-178-L. Epub 2015 Aug 3.

Abstract

OBJECTIVES

To evaluate the effect of the restorative protocol on cuspal strain, fracture resistance, residual stress, and mechanical properties of restorative materials in endodontically treated molars.

METHODS

Forty-five molars received mesio-occlusal-distal (MOD) Class II preparations and endodontic treatment followed by direct restorations using three restorative protocols: composite resin (CR) only (Filtek Supreme, 3M-ESPE), resin modified glass ionomer cement in combination with CR (Vitremer, 3M-ESPE in pulp chamber and Filtek Supreme in MOD cavity), conventional glass ionomer cement in combination with composite resin (CGI-CR) (Ketac Fil, 3M-ESPE in pulp chamber and Filtek Supreme in MOD cavity). Cuspal strain was measured using strain gauges, and fracture resistance was tested with an occlusal load. Elastic modulus (EM) and Vickers hardness (VH) of the restorative materials were determined at different depths using dynamic microhardness indentation. Curing shrinkage was measured using the strain gauge technique. The restorative protocols were also simulated in finite element analysis (FEA). The shrinkage strain, cuspal strain, EM, VH, and fracture resistance data were statistically analyzed using split-plot analysis of variance and Tukey test (p=0.05). Residual shrinkage stresses were expressed in modified von Mises equivalent stresses.

RESULTS

Shrinkage strain values (in volume %) were Ketac Fil (0.08±0.01) < Vitremer (0.18±0.01) < Filtek Supreme (0.54±0.03). Cuspal strain was higher and fracture resistance was lower when using CR only compared with the techniques that used glass ionomer. The EM and VH of the materials in the pulp chamber were significantly lower for glass ionomer. The FEA showed that using CR only resulted in higher residual stresses in enamel and root dentin close to the pulp chamber than the combinations with glass ionomers (RMGI-CR and CGI-CR).

CONCLUSIONS

The choice of restorative protocol significantly affected the biomechanical behavior of endodontically treated molars. Using glass ionomer to fill the pulp chamber is recommended when endodontically treated molars receive direct composite restorations because it reduces cuspal strain and increases fracture resistance.

摘要

目的

评估修复方案对根管治疗后磨牙牙尖应变、抗折强度、残余应力和修复材料力学性能的影响。

方法

45 颗磨牙行近中-颊-远中(MOD)Ⅱ类洞型预备和根管治疗,然后分别采用三种修复方案进行直接修复:复合树脂(CR)(Filtek Supreme,3M-ESPE)、玻璃离子水门汀与 CR 联合(Vitremer,3M-ESPE 于牙髓腔,Filtek Supreme 于 MOD 腔)、传统玻璃离子与复合树脂联合(CGI-CR)(Ketac Fil,3M-ESPE 于牙髓腔,Filtek Supreme 于 MOD 腔)。采用应变片测量牙尖应变,用牙合向载荷测试抗折强度。采用动态显微硬度压痕法在不同深度测量修复材料的弹性模量(EM)和维氏硬度(VH)。采用应变片技术测量固化收缩率。在有限元分析(FEA)中模拟修复方案。采用析因方差分析和 Tukey 检验(p=0.05)对收缩应变、牙尖应变、EM、VH 和抗折强度数据进行统计学分析。残余收缩应力以修正的 von Mises 等效应力表示。

结果

收缩应变值(以体积%计)为 Ketac Fil(0.08±0.01)<Vitremer(0.18±0.01)<Filtek Supreme(0.54±0.03)。与玻璃离子联合应用的技术相比,仅使用 CR 时牙尖应变更高,抗折强度更低。玻璃离子材料在牙髓腔内的 EM 和 VH 显著较低。FEA 显示,与玻璃离子联合应用(RMGI-CR 和 CGI-CR)相比,仅使用 CR 时在靠近牙髓腔的牙釉质和根牙本质中会产生更高的残余应力。

结论

修复方案的选择显著影响根管治疗后磨牙的生物力学行为。当根管治疗后的磨牙行直接复合树脂修复时,推荐使用玻璃离子填充牙髓腔,因为它可以降低牙尖应变,提高抗折强度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验