Butera Gianfranco, Taha Fatma
Pediatric Cardiology and GUCH Unit, Policlinico San Donato IRCCS, Milan, Italy.
Department of Cardiology, Cardiology, Tanta University, Tanta, Egypt.
Catheter Cardiovasc Interv. 2016 May;87(6):E240-2. doi: 10.1002/ccd.26158. Epub 2015 Aug 13.
Several issues may impact on the function of a Fontan circulation including accessory source of pulmonary blood flow and pulmonary artery anatomy. Here we report on a 5.5-year-old boy who showed failing Fontan circulation due to left pulmonary artery stenosis/hypoplasia and significant forward pulmonary blood flow through the native pulmonary artery. Successful implantation of a 34-mm CP covered stent in the left pulmonary artery in a Fontan patient was useful for simultaneous successful treatment of residual antegrade flow from the systemic ventricle to the pulmonary artery and enlargement of hypoplastic left pulmonary artery. © 2015 Wiley Periodicals, Inc.
几个问题可能会影响Fontan循环的功能,包括肺血流的辅助来源和肺动脉解剖结构。在此,我们报告一名5.5岁男孩,其因左肺动脉狭窄/发育不全以及通过天然肺动脉的大量正向肺血流而出现Fontan循环功能衰竭。在一名Fontan患者的左肺动脉成功植入一枚34毫米的覆膜CP支架,有助于同时成功治疗从体循环心室到肺动脉的残余顺行血流以及扩大发育不全的左肺动脉。© 2015威利期刊公司。