Bűhler Miranda, Johnson Gillian, Meikle Grant
Centre for Health, Activity and Rehabilitation Research, University of Otago, Dunedin, New Zealand; Physiotherapy Outpatient Department, Dunedin Hospital, Southern District Health Board, Dunedin, New Zealand.
Centre for Health, Activity and Rehabilitation Research, University of Otago, Dunedin, New Zealand.
Ultrasound Med Biol. 2015 Nov;41(11):3018-22. doi: 10.1016/j.ultrasmedbio.2015.07.006. Epub 2015 Aug 21.
The link between the healing process and functional outcomes in the surgically repaired digital flexor tendon is poorly understood. This clinical note describes those gray-scale and power Doppler (PD) ultrasound parameters that can be used to document longitudinal change in the morphologic and dynamic properties of the surgically repaired zone II flexor digitorum profundus (FDP) tendon. The method is supported by ultrasound data obtained from three participants at five points in time post-surgically (two, four, six, 12 and 18 weeks). Longitudinal documentation of the ultrasound properties of echogenicity, defect size, tendon excursion and power Doppler signal is feasible and has the potential to explore the possible link between changes in the structural status of surgically repaired flexor tendons and associated clinical outcomes.
手术修复的指屈肌腱愈合过程与功能结果之间的联系目前还知之甚少。本临床记录描述了那些灰阶和能量多普勒(PD)超声参数,这些参数可用于记录手术修复的Ⅱ区指深屈肌(FDP)肌腱形态和动态特性的纵向变化。该方法得到了三名参与者术后五个时间点(术后两周、四周、六周、12周和18周)的超声数据支持。对回声性、缺损大小、肌腱偏移和能量多普勒信号等超声特性进行纵向记录是可行的,并且有可能探索手术修复的屈肌腱结构状态变化与相关临床结果之间的可能联系。