Singhal Anubhav, Kumar Sudeep, Kapoor Aditya
Senior Resident, Dept. of Cardiology, Sanjay Gandhi PGIMS, Lucknow, India.
Additional Professor, Dept. of Cardiology, Sanjay Gandhi PGIMS, Lucknow, India.
Indian Heart J. 2015 Jul-Aug;67(4):406-8. doi: 10.1016/j.ihj.2015.06.043. Epub 2015 Jul 23.
It is important to obtain a good withdrawal pressure tracing while performing cardiac catheterization in cases with right ventricular outflow tract (RVOT) obstruction to document the site and severity of obstruction. However efforts to manipulate the catheter in the RVOT (either to obtain the gradients or to position the catheter for an outflow angiogram) can sometimes precipitate severe dynamic RVOT obstruction with complete cessation of forward flow leading to life threatening hypotension. The following hemodynamic traces highlight this rare phenomenon which needs to be borne in mind at all times while performing cardiac catheterization in such patients.
在右心室流出道(RVOT)梗阻的病例中进行心导管插入术时,获取良好的回撤压力曲线以记录梗阻部位和严重程度很重要。然而,在RVOT中操作导管(无论是获取压力阶差还是将导管定位以进行流出道血管造影)有时会引发严重的动态RVOT梗阻,导致前向血流完全停止,进而引起危及生命的低血压。以下血流动力学曲线突出了这种罕见现象,在对此类患者进行心导管插入术时必须始终牢记这一点。