To quantify maxillary sinus volume and mucosal surface area (SA) that is accessible endoscopically via a middle meatal antrostomy and to explore the financial implications of using multiple disposable instruments for this procedure.
Eight cadaver maxillary sinuses configured with image guidance software were evaluated. In each sinus, a standard middle meatal antrostomy was created, through which curved microdebriders of 15, 40, 70, and 120° were placed. The SA and volume of the region accessible by each microdebrider tip was calculated.
Mean maxillary sinus volume was 16.5 ± 2.5 cm(3) and mean SA was 31.0 ± 2.3 cm(2). The 15, 40, 70 and 120° microdebriders accessed an average of 10, 25, 41, and 66%, respectively, of the SA, and of 2, 9, 17, and 36%, respectively, of the volume. There was a trend toward improved accessibility of the superior half versus the inferior half of the maxillary sinus. When instruments of different degrees were combined to maximize accessibility, 81% of the SA of the sinus could be accessed.
Microdebriders with increasing curvatures allowed for greater access of the maxillary sinus mucosa through an middle meatal antrostomy. No single microdebrider curvature or combination of curvatures reached the entirety of the maxillary sinus wall. Knowledge about the area of reach for these blades can lead to lower per procedure costs.
量化经中鼻道上颌窦造口术可通过内镜进入的上颌窦容积和黏膜表面积(SA),并探讨在此手术中使用多种一次性器械的经济影响。
对8个配置了图像引导软件的尸体上颌窦进行评估。在每个窦中创建标准的中鼻道上颌窦造口术,通过该造口术放置15°、40°、70°和120°的弯曲微型清创器。计算每个微型清创器尖端可进入区域的SA和容积。
上颌窦平均容积为16.5±2.5 cm³,平均SA为31.0±2.3 cm²。15°、40°、70°和120°微型清创器分别平均可进入SA的10%、25%、41%和66%,以及容积的2%、9%、17%和36%。上颌窦上半部分与下半部分相比,可及性有改善的趋势。当组合不同角度的器械以最大化可及性时,可进入窦SA的81%。
曲率增加的微型清创器可通过中鼻道上颌窦造口术更广泛地进入上颌窦黏膜。没有单一的微型清创器曲率或曲率组合能够触及上颌窦壁的全部区域。了解这些刀片的可达区域可降低每次手术的成本。