Suppr超能文献

Size-specific Dose Estimates for Chest, Abdominal, and Pelvic CT: Effect of Intrapatient Variability in Water-equivalent Diameter.

作者信息

Leng Shuai, Shiung Maria, Duan Xinhui, Yu Lifeng, Zhang Yi, McCollough Cynthia H

出版信息

Radiology. 2015 Oct;277(1):308-9. doi: 10.1148/radiol.2015151209.

Abstract
摘要

相似文献

3
Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates.
J Radiol Prot. 2018 Jun;38(2):536-548. doi: 10.1088/1361-6498/aaa32c. Epub 2017 Dec 20.
4
Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction.
Phys Med. 2016 Feb;32(2):393-7. doi: 10.1016/j.ejmp.2015.12.008. Epub 2016 Jan 15.
5
How accurate is size-specific dose estimate in pediatric body CT examinations?
Pediatr Radiol. 2016 Aug;46(9):1234-40. doi: 10.1007/s00247-016-3604-0. Epub 2016 Apr 6.
6
Tailoring CT Dose to Patient Size: Implementation of the Updated 2017 ACR Size-specific Diagnostic Reference Levels.
Acad Radiol. 2018 Dec;25(12):1624-1631. doi: 10.1016/j.acra.2018.03.005. Epub 2018 Mar 23.
8
Automatic calculation of patient size metrics in computed tomography: What level of computational accuracy do we need?
J Appl Clin Med Phys. 2018 Jan;19(1):218-227. doi: 10.1002/acm2.12240. Epub 2017 Dec 19.
10
Effect of body size on dose reduction with longitudinal tube current modulation in pediatric patients.
AJR Am J Roentgenol. 2015 Apr;204(4):861-4. doi: 10.2214/AJR.14.12762.

引用本文的文献

1
Computed Tomography Doses Calculation: Do We Really Need a New Dose Assessment Tool?
J Clin Med. 2025 Feb 18;14(4):1348. doi: 10.3390/jcm14041348.
2
Using a Somatosensory Controller to Assess Body Size for Size-Specific Dose Estimates in Computed Tomography.
Biomed Res Int. 2018 May 31;2018:2734297. doi: 10.1155/2018/2734297. eCollection 2018.
3
A comparison study of size-specific dose estimate calculation methods.
Pediatr Radiol. 2018 Jan;48(1):56-65. doi: 10.1007/s00247-017-3986-7. Epub 2017 Sep 27.
4
Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT.
Acta Radiol Open. 2016 Aug 24;5(8):2058460116662299. doi: 10.1177/2058460116662299. eCollection 2016 Aug.
5
Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose.
Cancer Imaging. 2016 Jun 21;16(1):15. doi: 10.1186/s40644-016-0073-5.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验