A comparison of 2 evaporative cooling systems on a commercial dairy farm in Saudi Arabia.

作者信息

Ortiz X A, Smith J F, Villar F, Hall L, Allen J, Oddy A, Al-Haddad A, Lyle P, Collier R J

机构信息

Department of Animal Science, University of Arizona, Tucson 85719.

Department of Agricultural Sciences, Northwest Missouri State University, Maryville 64468.

出版信息

J Dairy Sci. 2015 Dec;98(12):8710-22. doi: 10.3168/jds.2015-9616. Epub 2015 Sep 26.

Abstract

Efficacy of 2 cooling systems (Korral Kool, KK, Korral Kool Inc., Mesa, AZ; FlipFan dairy system, FF, Schaefer Ventilation Equipment LLC, Sauk Rapids, MN) was estimated utilizing 400 multiparous Holstein dairy cows randomly assigned to 1 of 4 cooled California-style shade pens (2 shade pens per cooling system). Each shaded pen contained 100 cows (days in milk=58±39, milk production=56±18 kg/d, and lactation=3±1). Production data (milk yield and reproductive performance) were collected during 3mo (June-August, 2013) and physiological responses (core body temperature, respiration rates, surface temperatures, and resting time) were measured in June and July to estimate responses of cows to the 2 different cooling systems. Water and electricity consumption were recorded for each system. Cows in the KK system displayed slightly lower respiration rates in the month of June and lower surface temperatures in June and July. However, no differences were observed in the core body temperature of cows, resting time, feed intake, milk yield, services/cow, and conception rate between systems. The FF system used less water and electricity during this study. In conclusion, both cooling systems (KK and FF) were effective in mitigating the negative effects of heat stress on cows housed in arid environments, whereas the FF system consumed less water and electricity and did not require use of curtains on the shade structure.

摘要

利用400头经产荷斯坦奶牛评估了两种冷却系统(Korral Kool,KK,Korral Kool公司,亚利桑那州梅萨市;FlipFan奶牛系统,FF,谢弗通风设备有限责任公司,明尼苏达州索克 Rapids)的效果,这些奶牛被随机分配到4个加利福尼亚式带阴凉处的围栏中的1个(每个冷却系统2个带阴凉处的围栏)。每个带阴凉处的围栏容纳100头奶牛(泌乳天数 = 58±39天,产奶量 = 56±18千克/天,泌乳期 = 3±1)。在2013年6月至8月的3个月期间收集生产数据(产奶量和繁殖性能),并在6月和7月测量生理反应(核心体温、呼吸频率、体表温度和休息时间),以评估奶牛对两种不同冷却系统的反应。记录每个系统的水和电消耗情况。KK系统中的奶牛在6月份的呼吸频率略低,在6月和7月的体表温度较低。然而,在不同系统之间,奶牛的核心体温、休息时间、采食量、产奶量、每头奶牛的配种次数和受孕率没有差异。在本研究中,FF系统消耗的水和电较少。总之,两种冷却系统(KK和FF)都能有效减轻炎热环境对奶牛热应激的负面影响,而FF系统消耗的水和电较少,并且在阴凉结构上不需要使用帘子。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验