Suppr超能文献

藻酸盐牙科印模材料的尺寸变化——一项体外研究

Dimensional Changes of Alginate Dental Impression Materials-An Invitro Study.

作者信息

Kulkarni Manisha M, Thombare Ram U

机构信息

Reader, Department of Prosthodontics, Yashwant Rao Chauhan Dental College , Ahmednagar, Maharashtra, India .

Professor & HOD, Department of Prosthodontics, Sharad Pawar Dental College , Wardha. Maharashtra, India .

出版信息

J Clin Diagn Res. 2015 Aug;9(8):ZC98-ZC102. doi: 10.7860/JCDR/2015/13627.6407. Epub 2015 Aug 1.

Abstract

BACKGROUND

Dentists are always looking ahead for more dimensionally stable material for accurate and successful fabrication of prosthesis in this competitive world. Arrival of newer materials and increased material market puts dentists in dilemma for selection of material.

AIM

The study evaluated the effect of variations in time of pour and temperature on dimensional stability of three brands of commercially available alginates.

MATERIALS AND METHODS

Velplast, Marieflex & Zelgan alginate impression materials were evaluated by measuring dimensional accuracy of the master cast. A die was prepared and mounted on the apparatus for the ease of impression making. The prepared casts were categorized into five groups and made up of three brands of alginate impression material with variation in time of pour viz: immediate, 20&40 minutes interval and with varying temperature of 25(0)C, 30(0)C & 40(0)C.

RESULTS

Impressions showed least distortion at varying degrees of temperature for 20 minutes, but the values obtained by storing of alginate impressions for 20 minutes at 30(0)C were found to be nearly accurate than the values obtained by storing of impression at 40(0)C. However, storing showed shrinkage of impressions.

CONCLUSION

Marieflex showed better accuracy in comparison with other two materials. Maintenance of temperature and humidity play key role during storage & transport to prevent distortion. But the study suggests immediate pouring which will minimize the distortion. The manipulation instructions, temperature of mixing water, environment & water powder ratio also plays key role in minimizing the distortion.

摘要

背景

在这个竞争激烈的世界里,牙医们一直在寻找尺寸更稳定的材料,以便准确、成功地制作假牙。新材料的出现和材料市场的扩大让牙医在材料选择上陷入两难境地。

目的

本研究评估灌注时间和温度的变化对三种市售藻酸盐材料尺寸稳定性的影响。

材料与方法

通过测量母模的尺寸精度来评估Velplast、Marieflex和Zelgan藻酸盐印模材料。制备一个模具并安装在仪器上,以便于制作印模。将制备好的铸模分为五组,由三种藻酸盐印模材料组成,灌注时间不同,即立即灌注、间隔20分钟和40分钟,温度也不同,分别为25℃、30℃和40℃。

结果

印模在不同温度下20分钟时变形最小,但在30℃下储存20分钟得到的值比在40℃下储存印模得到的值更接近准确值。然而,储存显示印模有收缩。

结论

与其他两种材料相比,Marieflex表现出更好的准确性。在储存和运输过程中,保持温度和湿度对防止变形起着关键作用。但该研究建议立即灌注以尽量减少变形。操作说明、调拌水温度、环境和水粉比在尽量减少变形方面也起着关键作用。

相似文献

1
Dimensional Changes of Alginate Dental Impression Materials-An Invitro Study.
J Clin Diagn Res. 2015 Aug;9(8):ZC98-ZC102. doi: 10.7860/JCDR/2015/13627.6407. Epub 2015 Aug 1.
4
Dimensional stability of alginate impression material over a four hours time frame.
Nig Q J Hosp Med. 2007 Jan-Mar;17(1):1-4. doi: 10.4314/nqjhm.v17i1.12531.
6
Accuracy and dimensional stability of extended-pour and conventional alginate impression materials.
J Am Dent Assoc. 2010 Jan;141(1):32-9. doi: 10.14219/jada.archive.2010.0018.
10
Dimensional changes of extended-pour alginate impression materials.
Am J Orthod Dentofacial Orthop. 2013 Apr;143(4 Suppl):S55-63. doi: 10.1016/j.ajodo.2012.06.016.

引用本文的文献

1
Comparative Analysis of Alginate Dimensional Stability with Varied Pouring Intervals.
J Pharm Bioallied Sci. 2024 Dec;16(Suppl 5):S4599-S4603. doi: 10.4103/jpbs.jpbs_762_24. Epub 2025 Jan 30.
2
The Prevalence of Alveolar Ridge Defects According to Seibert's Classification: A Cross-Sectional Study.
Cureus. 2024 Dec 12;16(12):e75602. doi: 10.7759/cureus.75602. eCollection 2024 Dec.
4
Conventional Dental Impressions vs. Impressions Reinforced with Rigid Mouthguards.
Polymers (Basel). 2024 Apr 4;16(7):994. doi: 10.3390/polym16070994.
6
The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials.
Heliyon. 2020 Jan 14;6(1):e03143. doi: 10.1016/j.heliyon.2019.e03143. eCollection 2020 Jan.
7
Accuracy of a smartphone-based orthodontic treatment-monitoring application: .
Angle Orthod. 2019 Sep;89(5):727-733. doi: 10.2319/100218-710.1. Epub 2019 Mar 19.
8
Influence of the material for preformed moulds on the polymerization temperature of resin materials for temporary FPDs.
J Adv Prosthodont. 2017 Aug;9(4):294-301. doi: 10.4047/jap.2017.9.4.294. Epub 2017 Aug 16.

本文引用的文献

2
Accuracy and dimensional stability of extended-pour and conventional alginate impression materials.
J Am Dent Assoc. 2010 Jan;141(1):32-9. doi: 10.14219/jada.archive.2010.0018.
3
Determination of bound and unbound water in dental alginate irreversible hydrocolloid by nuclear magnetic resonance spectroscopy.
Dent Mater. 2009 Apr;25(4):486-93. doi: 10.1016/j.dental.2008.10.001. Epub 2008 Nov 18.
5
Dimensional changes of alginate dental impression materials.
J Mater Sci Mater Med. 2006 Dec;17(12):1205-10. doi: 10.1007/s10856-006-0593-9.
6
Effect of mixing methods on mechanical properties of alginate impression materials.
J Prosthodont. 2005 Dec;14(4):221-5. doi: 10.1111/j.1532-849X.2005.00047.x.
8
Effects of long-term storage on properties of an alginate impression material.
J Prosthet Dent. 1997 Jun;77(6):601-6. doi: 10.1016/s0022-3913(97)70102-1.
9
Dimensional accuracy of three different alginate impression materials.
J Prosthodont. 1995 Sep;4(3):195-9. doi: 10.1111/j.1532-849x.1995.tb00340.x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验