Abstract

BACKGROUND

Lack of specificity of anti-PGE2 antibodies is a long-standing problem. Given quite a few analogs and low PGE2 content in biological fluids, it is quite important to simultaneously meet the demands of high specificity and sensitivity.

RESULTS

Highly specific anti-PGE2 antibodies were obtained by combined use of cationic carrier protein and Mannich reaction. The cross-reactivity values of the resultant polyclonal and monoclonal antibodies against eight analogs were <14 and <5%, respectively. Furthermore, we established a highly sensitive ELISA, which could be applied to direct analysis of PGE2 at the pg/ml level (LOQ = 15.6 pg/ml).

CONCLUSION

We provide an appropriate strategy to develop a highly-specific and sensitive immunoassay for measuring low PGE2 content in biological samples.

摘要

背景

抗前列腺素E2(PGE2)抗体缺乏特异性是一个长期存在的问题。鉴于生物体液中有不少类似物且PGE2含量较低,同时满足高特异性和高灵敏度的要求非常重要。

结果

通过阳离子载体蛋白与曼尼希反应联合使用获得了高度特异性的抗PGE2抗体。所得多克隆抗体和单克隆抗体对八种类似物的交叉反应值分别<14%和<5%。此外,我们建立了一种高灵敏度的酶联免疫吸附测定法(ELISA),可用于直接分析pg/ml水平的PGE2(定量下限=15.6 pg/ml)。

结论

我们提供了一种合适的策略,用于开发一种高特异性和高灵敏度的免疫测定法,以测量生物样品中低含量的PGE2。