Suppr超能文献

不同小腿加压袖套对组织氧饱和度的影响

Changes in Tissue Oxygen Saturation in Response to Different Calf Compression Sleeves.

作者信息

Dermont T, Morizot L, Bouhaddi M, Ménétrier A

机构信息

EA3920 Marqueurs Pronostiques et Facteurs de Régulations des Pathologies Cardiaques et Vasculaires, Plateforme Exercice Performance Santé Innovation, SFR FED 4234, Université de Franche-Comté, Besançon, France ; Université Savoie Mont Blanc, Chambéry, France.

EA3920 Marqueurs Pronostiques et Facteurs de Régulations des Pathologies Cardiaques et Vasculaires, Plateforme Exercice Performance Santé Innovation, SFR FED 4234, Université de Franche-Comté, Besançon, France.

出版信息

J Sports Med (Hindawi Publ Corp). 2015;2015:857904. doi: 10.1155/2015/857904. Epub 2015 Sep 8.

Abstract

Aim. The purpose was to examine the changes in tissue oxygen saturation (StO2) in response to the application of different commercially available calf compression sleeves. Methods. Eight subjects came to the laboratory to complete a session in seated position including 10 min of quiet rest followed by 3 min measuring calf StO2 without compression sleeves and then alternating of 3 min of passive rest and 3 min measuring StO2 with calf compression sleeves. A total of 15 different commercially available compression sleeves were studied in a randomized order. Calf StO2 was recorded using near-infrared spectroscopy. Results. StO2 was significantly increased with all compression sleeves (p < 0.05) compared with no compression (from +6.9% for the least effective to +22.6% for the most effective). Large differences were observed between compression sleeves (p < 0.05). StO2 was positively correlated with compression pressure (p < 0.05; r = 0.84). Conclusion. This study shows that wearing compression sleeves from various brands differently affects tissue oxygen saturation. Differences were linked to the compression pressure: higher compression pressures were associated with higher StO2.

摘要

目的。本研究旨在探讨使用不同市售小腿加压套后组织氧饱和度(StO2)的变化情况。方法。8名受试者来到实验室,在坐姿下完成一个测试环节,包括10分钟的安静休息,然后在不使用加压套的情况下测量3分钟小腿StO2,之后交替进行3分钟的被动休息和3分钟使用小腿加压套测量StO2。总共对15种不同的市售加压套进行了随机研究。使用近红外光谱法记录小腿StO2。结果。与不使用加压套相比,所有加压套均使StO2显著增加(p < 0.05)(从效果最差的增加6.9%到效果最好的增加22.6%)。不同加压套之间观察到显著差异(p < 0.05)。StO2与加压压力呈正相关(p < 0.05;r = 0.84)。结论。本研究表明,佩戴不同品牌的加压套对组织氧饱和度的影响不同。差异与加压压力有关:较高的加压压力与较高的StO2相关。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3e85/4590978/a815a6d5e31b/JSM2015-857904.001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验