Suppr超能文献

基于计算机断层扫描灌注采集的时间分辨C型臂计算机断层血管造影术:血管造影套件中一站式急性缺血性卒中治疗的新能力。

Time-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition: New Capability for One-Stop-Shop Acute Ischemic Stroke Treatment in the Angiosuite.

作者信息

Yang Pengfei, Niu Kai, Wu Yijing, Struffert Tobias, Dorfler Arnd, Schafer Sebastian, Royalty Kevin, Strother Charles, Chen Guang-Hong

机构信息

From the Department of Neurosurgery, Changhai Hospital, Second Military Medical University, Shanghai, China (P.Y.); Departments of Radiology (P.Y., C.S., G.-H.C.) and Medical Physics (K.N., Y.W., G.-H.C.), University of Wisconsin-Madison; Department of Neuroradiology, University of Erlangen-Nuremberg, Erlangen, Germany (T.S., A.D.); and Department of Research Collaboration, Siemens Medical Solutions, USA, Inc, Hoffman Estates, IL (S.S., K.R.).

出版信息

Stroke. 2015 Dec;46(12):3383-9. doi: 10.1161/STROKEAHA.115.011165. Epub 2015 Oct 22.

Abstract

BACKGROUND AND PURPOSE

Multimodal imaging using cone beam C-arm computed tomography (CT) may shorten the delay from ictus to revascularization for acute ischemic stroke patients with a large vessel occlusion. Largely because of limited temporal resolution, reconstruction of time-resolved CT angiography (CTA) from these systems has not yielded satisfactory results. We evaluated the image quality and diagnostic value of time-resolved C-arm CTA reconstructed using novel image processing algorithms.

METHODS

Studies were done under an Institutional Review Board approved protocol. Postprocessing of data from 21 C-arm CT dynamic perfusion acquisitions from 17 patients with acute ischemic stroke were done to derive time-resolved C-arm CTA images. Two observers independently evaluated image quality and diagnostic content for each case. ICC and receiver-operating characteristic analysis were performed to evaluate interobserver agreement and diagnostic value of this novel imaging modality.

RESULTS

Time-resolved C-arm CTA images were successfully generated from 20 data sets (95.2%, 20/21). Two observers agreed well that the image quality for large cerebral arteries was good but was more limited for small cerebral arteries (distal to M1, A1, and P1). receiver-operating characteristic curves demonstrated excellent diagnostic value for detecting large vessel occlusions (area under the curve=0.987-1).

CONCLUSIONS

Time-resolved CTAs derived from C-arm CT perfusion acquisitions provide high quality images that allowed accurate diagnosis of large vessel occlusions. Although image quality of smaller arteries in this study was not optimal ongoing modifications of the postprocessing algorithm will likely remove this limitation. Adding time-resolved C-arm CTAs to the capabilities of the angiography suite further enhances its suitability as a one-stop shop for care for patients with acute ischemic stroke.

摘要

背景与目的

使用锥形束C型臂计算机断层扫描(CT)进行多模态成像可能会缩短急性大血管闭塞性缺血性卒中患者从发病到血管再通的延迟时间。很大程度上由于时间分辨率有限,从这些系统重建时间分辨CT血管造影(CTA)并未取得令人满意的结果。我们评估了使用新型图像处理算法重建的时间分辨C型臂CTA的图像质量和诊断价值。

方法

研究在机构审查委员会批准的方案下进行。对17例急性缺血性卒中患者的21次C型臂CT动态灌注采集数据进行后处理,以获得时间分辨C型臂CTA图像。两名观察者独立评估每个病例的图像质量和诊断内容。进行组内相关系数(ICC)和受试者操作特征分析,以评估观察者间的一致性和这种新型成像方式的诊断价值。

结果

从20个数据集(95.2%,20/21)成功生成了时间分辨C型臂CTA图像。两名观察者一致认为,大脑大动脉的图像质量良好,但大脑小动脉(M1、A1和P1远端)的图像质量更有限。受试者操作特征曲线显示,检测大血管闭塞具有优异的诊断价值(曲线下面积=0.987 - 1)。

结论

从C型臂CT灌注采集中获得的时间分辨CTA提供了高质量图像,能够准确诊断大血管闭塞。尽管本研究中小动脉的图像质量并非最佳,但对后处理算法的持续改进可能会消除这一限制。将时间分辨C型臂CTA添加到血管造影设备的功能中,进一步提高了其作为急性缺血性卒中患者一站式护理场所的适用性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验