孕晚期使用多普勒测速法测量脑、脐和子宫血流阻力。

Cerebral, umbilical, and uterine resistance using Doppler velocimetry in postterm pregnancy.

作者信息

Brar H S, Horenstein J, Medearis A L, Platt L D, Phelan J P, Paul R H

机构信息

Department of Obstetrics and Gynecology, University of Southern California School of Medicine, Los Angeles.

出版信息

J Ultrasound Med. 1989 Apr;8(4):187-91. doi: 10.7863/jum.1989.8.4.187.

Abstract

The purpose of this study is to assess alterations in vascular resistance as measured by Doppler ultrasound in the postterm fetus. Forty-five postterm patients (greater than or equal to 287 days gestation by "good" dates) underwent Doppler velocimetry and calculation of systolic to diastolic (S/D) ratios of the umbilical, internal carotid, and uterine artery waveforms within 7 days of delivery. Patients were divided into two groups. Group 1 consisted of 26 patients with normal antepartum fetal surveillance that included reactive nonstress test and an amniotic fluid index (using the four-quadrant technique) equal to or greater than 5 cm. Group 2 consisted of 19 patients with antepartum compromise on the antepartum fetal surveillance tests. There was significantly greater (p less than .05) morbidity in group 2 compared to group 1 as judged by cesarean section for fetal distress (47% vs 15%), meconium at delivery (53% vs 4%), and 5-minute Apgar score less than 7 (30% vs 4%). There were no significant differences in the umbilical and uterine artery S/D ratios in the two groups, although patients in group 2 had significantly lower cerebral S/D ratios (3.6 +/- .5) compared to group 1 (4.4 +/- 0.4) (p less than .05). The ratio of cerebral to placental (umbilical) resistance in group 2 was significantly lower (1.1 +/- .3) compared to group 1 (1.8 +/- .3) (p less than .05). There was a low incidence of abnormal umbilical (greater than 3) and uterine (greater than 2.6) S/D ratios in both groups.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究的目的是评估通过多普勒超声测量的过期胎儿血管阻力的变化。45例过期妊娠患者(根据“准确”孕周妊娠≥287天)在分娩后7天内接受了多普勒测速,并计算了脐动脉、颈内动脉和子宫动脉波形的收缩期与舒张期(S/D)比值。患者分为两组。第1组由26例产前胎儿监护正常的患者组成,包括反应型无应激试验和羊水指数(采用四象限技术)等于或大于5cm。第2组由19例产前胎儿监护试验显示有产前并发症的患者组成。根据因胎儿窘迫行剖宫产的情况(47%对15%)、分娩时羊水粪染的情况(53%对4%)以及5分钟阿氏评分低于7分的情况(30%对4%)判断,第2组的发病率显著高于第1组(p<0.05)。两组的脐动脉和子宫动脉S/D比值无显著差异,尽管第2组患者的脑S/D比值(3.6±0.5)显著低于第1组(4.4±0.4)(p<0.05)。第2组的脑与胎盘(脐)阻力比值(1.1±0.3)显著低于第1组(1.8±0.3)(p<0.05)。两组中脐动脉(>3)和子宫动脉(>2.6)S/D比值异常的发生率均较低。(摘要截选至250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验