Abstract

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been widely utilized for the analysis of compounds in biological matrices due to its selectivity and sensitivity. This study describes the application of an LC-MS/MS-based approach toward the analysis of cobinamide in Yorkshire pig plasma. The selectivity, accuracy, precision, recovery, linearity, range, carryover, sensitivity, matrix effect, interference, stability, reproducibility, and ruggedness of the method were investigated in pig plasma. The accuracy and precision of the method was determined to be within 10% over three different days over a range of concentrations (25-10,000ng/mL) that spanned more than two orders of magnitude. The lower limit of quantitation (LLOQ) for dicyanocobinamide was determined to be 25ng/mL in pig plasma. Carryover was acceptable, as the area response of the carryover blanks were ≤15% of the area response of the nearest LLOQ standard for the analyte, while it was nonexistent for the internal standard. Specificity was ensured using six different lots of pig plasma. While the matrix effects of dicyanocobinamide in plasma were enhanced, ginsenoside Rb1 experienced signal suppression under the described conditions. The absolute recovery results for both compounds were consistent, precise, and reproducibly lower than expected at ∼60% for dicyanocobinamide and ∼22% for ginsenoside Rb1, confirming that a matrix standard curve was required for accurate quantitation. Cobinamide was shown to be very stable in matrix at various storage conditions including room temperature, refrigerated, and frozen at time intervals of 20h, 4 days, and 60 days respectively. This method was demonstrated to be sensitive, reproducible, stable, and rugged, and it should be applicable to the analysis of cobinamide in other biological matrices and species.

摘要

液相色谱-串联质谱法(LC-MS/MS)因其选择性和灵敏度,已被广泛用于分析生物基质中的化合物。本研究描述了一种基于LC-MS/MS的方法在约克郡猪血浆中钴胺酰胺分析的应用。该方法在猪血浆中进行了选择性、准确性、精密度、回收率、线性、范围、残留、灵敏度、基质效应、干扰、稳定性、重现性和耐用性研究。该方法在跨越两个多数量级的一系列浓度(25-10,000ng/mL)下,在三天内的准确性和精密度被确定在10%以内。猪血浆中双氰钴胺的定量下限(LLOQ)被确定为25ng/mL。残留是可接受的,因为残留空白的面积响应≤分析物最近LLOQ标准面积响应的15%,而内标不存在残留。使用六批不同的猪血浆确保了特异性。虽然血浆中双氰钴胺的基质效应增强,但在所描述的条件下人参皂苷Rb1经历了信号抑制。两种化合物的绝对回收率结果一致、精确且可重现,低于预期,双氰钴胺约为60%,人参皂苷Rb1约为22%,证实了准确定量需要基质标准曲线。已证明钴胺酰胺在各种储存条件下在基质中非常稳定,包括室温、冷藏和冷冻,时间间隔分别为20小时、4天和60天。该方法被证明是灵敏、可重现、稳定和耐用的,并且应该适用于分析其他生物基质和物种中的钴胺酰胺。

相似文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验