燃煤电厂湿法烟气脱硫洗涤器中硒的分配与去除。

Selenium Partitioning and Removal Across a Wet FGD Scrubber at a Coal-Fired Power Plant.

机构信息

ADA-ES, Inc., 9135 S. Ridgeline Blvd., Suite 200, Highlands Ranch, Colorado 80129, United States.

Southern Research, 2000 Ninth Avenue South, Birmingham, Alabama 35205, United States.

出版信息

Environ Sci Technol. 2015 Dec 15;49(24):14376-82. doi: 10.1021/acs.est.5b03722. Epub 2015 Nov 23.

Abstract

Selenium has unique fate and transport through a coal-fired power plant because of high vapor pressures of oxide (SeO2) in flue gas. This study was done at full-scale on a 900 MW coal-fired power plant with electrostatic precipitator (ESP) and wet flue gas desulfurization (FGD) scrubber. The first objective was to quantify the partitioning of selenium between gas and condensed phases at the scrubber inlet and outlet. The second objective was to determine the effect of scrubber operation conditions (pH, mass transfer, SO2 removal) on Se removal in both particulate and vapor phases. During part of the testing, hydrated lime (calcium hydroxide) was injected upstream of the scrubber. Gas-phase selenium and particulate-bound selenium were measured as a function of particle size at the inlet and outlet of the scrubber. The total (both phases) removal of Se across the scrubber averaged 61%, and was enhanced when hydrated lime sorbent was injected. There was evidence of gas-to-particle conversion of selenium across the scrubber, based on the dependence of selenium concentration on particle diameter downstream of the scrubber and on thermodynamic calculations.

摘要

由于烟道气中氧化硒(SeO2)的蒸汽压较高,硒在燃煤电厂中具有独特的赋存和迁移特性。本研究在配备静电除尘器(ESP)和湿法烟气脱硫(FGD)洗涤器的 900MW 燃煤电厂进行了全规模试验。第一个目标是量化在洗涤器进出口处硒在气相和凝聚相之间的分配。第二个目标是确定洗涤器操作条件(pH 值、传质、SO2 去除率)对颗粒物相和蒸气相硒去除的影响。在部分测试期间,在洗涤器上游注入熟石灰(氢氧化钙)。以粒径为函数,在洗涤器进出口处测量气相硒和颗粒结合态硒。整个洗涤器(两相)对硒的总去除率平均为 61%,当注入熟石灰吸附剂时会增强。根据洗涤器下游硒浓度与粒径的关系以及热力学计算,有证据表明硒在洗涤器中发生了从气相到颗粒相的转化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验