Sales Carlos, Portolés Tania, Sancho Juan Vicente, Abad Esteban, Ábalos Manuela, Sauló Jordi, Fiedler Heidelore, Gómara Belén, Beltrán Joaquim
Research Institute for Pesticides and Water, University Jaume I, 12071, Castellón, Spain.
Laboratory of Dioxins, IDAEA, CSIC, 08034, Barcelona, Spain.
Anal Bioanal Chem. 2016 Jan;408(2):449-59. doi: 10.1007/s00216-015-9146-8. Epub 2015 Nov 11.
A fast method for the screening and quantification of hexabromocyclododecane (sum of all isomers) by gas chromatography using a triple quadrupole mass spectrometer with atmospheric pressure chemical ionization (GC-APCI-QqQ) is proposed. This novel procedure makes use of the soft atmospheric pressure chemical ionization source, which results in less fragmentation of the analyte than by conventional electron impact (EI) and chemical ionization (CI) sources, favoring the formation of the M - Br ion and, thus, enhancing sensitivity and selectivity. Detection was based on the consecutive loses of HBr from the M - Br ion to form the specific M - H5Br6 and M - H4Br5 ions, which were selected as quantitation (Q) and qualification (q) transitions, respectively. Parameters affecting ionization and MS/MS detection were studied. Method performance was also evaluated; calibration curves were found linear from 1 pg/μL to 100 pg/μL for the total HBCD concentration; instrumental detection limit was estimated to be 0.10 pg/μL; repeatability and reproducibility, expressed as relative standard deviation, were better than 7% in both cases. The application to different real samples [polyurethane foam disks (PUFs), food, and marine samples] pointed out a rapid way to identify and allow quantification of this compound together with a number of polybrominated diphenyl ethers (BDE congeners 28, 47, 66, 85, 99, 100, 153, 154, 183, 184, 191, 196, 197, and 209) and two other novel brominated flame retardants [i.e., decabromodiphenyl ethane (DBDPE) and 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE)] because of their presence in the same fraction when performing the usual sample treatment.
提出了一种使用具有大气压化学电离功能的三重四极杆质谱仪的气相色谱法快速筛选和定量六溴环十二烷(所有异构体总和)的方法(GC-APCI-QqQ)。这种新方法利用了软大气压化学电离源,与传统的电子轰击(EI)和化学电离(CI)源相比,该源导致分析物的碎片化程度更低,有利于M - Br离子的形成,从而提高了灵敏度和选择性。检测基于M - Br离子连续失去HBr形成特定的M - H5Br6和M - H4Br5离子,分别将其选为定量(Q)和定性(q)离子对。研究了影响电离和MS/MS检测的参数。还评估了方法性能;总六溴环十二烷浓度的校准曲线在1 pg/μL至100 pg/μL范围内呈线性;仪器检测限估计为0.10 pg/μL;重复性和再现性以相对标准偏差表示,在两种情况下均优于7%。对不同实际样品[聚氨酯泡沫盘(PUF)、食品和海洋样品]的应用指出了一种快速识别和定量该化合物以及多种多溴二苯醚(BDE同系物28、47、66、85、99、100、153、154、183、184、191、196、197和209)以及另外两种新型溴化阻燃剂[即十溴二苯醚(DBDPE)和1,2-双(2,4,6-三溴苯氧基)乙烷(BTBPE)]的方法,因为在进行常规样品处理时它们存在于同一馏分中。