Suppr超能文献

应用渐进式加压吻合器后离体肺活检的膨胀压力

Inflation Pressures for Ex Vivo Lung Biopsies After Application of Graduated Compression Staples.

作者信息

Imhoff Darren J, Monnet Eric

机构信息

Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, Colorado.

出版信息

Vet Surg. 2016 Jan;45(1):79-82. doi: 10.1111/vsu.12420. Epub 2015 Nov 23.

Abstract

OBJECTIVE

To compare 2 graduated compression staples (Tri-Staple™, Covidien, Norwalk, CT) and standard staples (Endo GIA™, Covidien) for lung biopsy in dogs.

STUDY DESIGN

Ex vivo experimental study, randomized, unblocked.

ANIMALS

Lung lobes (n = 18) from 4 canine cadavers.

METHODS

Eighteen lung lobes were harvested from 4 dogs immediately after euthanasia and randomized to 1 of 3 staples (n = 6 per stapler type). Each lung lobe was intubated and maintained inflated at 10 cmH2O. A biopsy of the periphery of each lung lobe was taken approximately 3 cm from the edge with a stapling device; the Tri-Staple™ medium/thick (TST), Tri-Staple™ vascular/medium (TSV), and Endo GIA™ 45-2.5 (EG). Each lobe was inflated to a maximum of 45 cmH2O of water to determine the pressure at which air leakage occurred (leak pressure).

RESULTS

The mean (95% confidence interval) leak pressure was 38.0 cmH2O (33.1-42.9) for EG, 29.2 (24.3-34.0) for TSV, and 26.0 (21.1-30.9) for TST. The mean leak pressure was significantly higher for EG than TSV (P = .016) and for EG than TST (P = .002), but was not different between TSV and TST (P = .344). One TSV leaked at 20 cmH2O and 1 TST leaked at 17 cmH2O. The surface area of the biopsy samples was not significantly different for staple types (P = .183).

CONCLUSION

Both TST and TSV leaked at significantly lower airway pressures than EG and may not be suitable for canine lung biopsy as some specimens leaked at pressures of 20 cmH2O or less.

摘要

目的

比较两种用于犬肺活检的带刻度吻合钉(Tri-Staple™,柯惠医疗,诺沃克,康涅狄格州)和标准吻合钉(Endo GIA™,柯惠医疗)。

研究设计

离体实验研究,随机、无阻碍。

动物

4只犬尸体的肺叶(n = 18)。

方法

安乐死后立即从4只犬获取18个肺叶,并随机分为3种吻合钉中的1种(每种吻合钉类型n = 6)。每个肺叶插管并维持在10 cmH₂O充气状态。使用吻合器械在每个肺叶边缘约3 cm处取外周活检样本;分别使用Tri-Staple™中/厚型(TST)、Tri-Staple™血管/中型(TSV)和Endo GIA™ 45-2.5(EG)。每个肺叶充气至最大45 cmH₂O水压以确定发生漏气时的压力(漏气压力)。

结果

EG的平均(95%置信区间)漏气压力为38.0 cmH₂O(33.1 - 42.9),TSV为29.2(24.3 - 34.0),TST为26.0(21.1 - 30.9)。EG的平均漏气压力显著高于TSV(P = 0.016)以及显著高于TST(P = 0.002),但TSV和TST之间无差异(P = 0.344)。1个TSV在20 cmH₂O时漏气,1个TST在17 cmH₂O时漏气。不同吻合钉类型的活检样本表面积无显著差异(P = 0.183)。

结论

TST和TSV在气道压力显著低于EG时就发生漏气,并且可能不适用于犬肺活检,因为一些样本在压力20 cmH₂O或更低时就发生了漏气。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验