Suppr超能文献

[锁定重建钢板治疗髋臼横形骨折不同内固定方式的生物力学研究]

[BIOMECHANICAL RESEARCH OF DIFFERENT INTERNAL FIXATIONS USING LOCKING RECONSTRUCTION PLATE FOR ACETABULAR TRANSVERSE FRACTURE].

作者信息

Liu Hongyang, Li Ligeng, Wu Xiaobo, Xu Hongjia, Zhang Ruijie

出版信息

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2015 Sep;29(9):1084-7.

Abstract

OBJECTIVE

To compare the biomechanical stability of acetabular transverse fracture fixed with single column locking reconstruction plate, locking reconstruction plate combined with lag screw, and double columns lag screws.

METHODS

Acetabular transverse fractures were established in 20 adult fresh semi-pelvis specimens, and divided into 5 groups randomly (n=4). The anterior columns were fixed with locking reconstruction plates in group A; the posterior columns were fixed with locking reconstruction plates in group B; the anterior columns were fixed with locking reconstruction plates and the posterior columns with lag screws in group C; the anterior columns were fixed with lag screws and the posterior columns with locking reconstruction plates in group D; the double columns were fixed with lag screws in group E. When loading three times weight, the longitudinal displacement of fracture fragment was measured, and the shear rigidity was calculated to compare the stability among groups.

RESULTS

The longitudinal displacement of groups A and B were significantly greater than that of groups C, D, and E (P<0.05), and the shear rigidity of groups A and B were significantly lower than that of groups C, D, and E (P< 0.05). The longitudinal displacement of group B was significantly greater than that of group A (P< 0.05), but no significant difference was found in the shear rigidity between groups A and B (P>0.05). There was no significant difference in the longitudinal displacement and shear rigiditramong groups C, D, and E (P>0.05).

CONCLUSION

Locking reconstruction plate combined with lag screw and double columns lag screws have similar stability, they have stronger stability than the single column locking reconstruction plate. The stability of anterior column locking reconstruction plate is better than that of the posterior column locking reconstruction plate.

摘要

目的

比较单柱锁定重建钢板、锁定重建钢板联合拉力螺钉及双柱拉力螺钉固定髋臼横行骨折的生物力学稳定性。

方法

选取20个成年新鲜半骨盆标本建立髋臼横行骨折模型,随机分为5组(n = 4)。A组采用锁定重建钢板固定前柱;B组采用锁定重建钢板固定后柱;C组采用锁定重建钢板固定前柱,拉力螺钉固定后柱;D组采用拉力螺钉固定前柱,锁定重建钢板固定后柱;E组采用双柱拉力螺钉固定。加载3倍体重时,测量骨折块的纵向位移,并计算剪切刚度以比较各组间的稳定性。

结果

A组和B组的纵向位移显著大于C组、D组和E组(P < 0.05),A组和B组的剪切刚度显著低于C组、D组和E组(P < 0.05)。B组的纵向位移显著大于A组(P < 0.05),但A组和B组的剪切刚度差异无统计学意义(P > 0.05)。C组、D组和E组的纵向位移和剪切刚度差异无统计学意义(P > 0.05)。

结论

锁定重建钢板联合拉力螺钉与双柱拉力螺钉具有相似的稳定性,它们比单柱锁定重建钢板具有更强的稳定性。前柱锁定重建钢板的稳定性优于后柱锁定重建钢板。