Vijayvergiya Rajesh, Sharma Prafull, Gupta Ankush, Goyal Praveg, Panda Prashant
Department of Cardiology, Post Graduate Institute of Medical Education & Research, Chandigarh -160012, India.
Department of Cardiology, Post Graduate Institute of Medical Education & Research, Chandigarh -160012, India.
Cardiovasc Revasc Med. 2016 Mar;17(2):143-5. doi: 10.1016/j.carrev.2015.12.004. Epub 2015 Dec 24.
A distortion of implanted coronary stent along its longitudinal axis during coronary intervention is known as longitudinal stent deformation (LSD). LSD is frequently seen with newer drug eluting stents (DES), specifically with PROMUS Element stent. It is usually caused by impact of guide catheter tip, or following passage of catheters like balloon catheter, IVUS catheter, guideliner, etc. We hereby report a case of LSD during coronary bifurcation lesion intervention, using two-stents technique. Patient had acute stent thrombosis as a complication of LSD, which was successfully managed.