Suppr超能文献

基于载体的热塑牙胶充填根管后根管预备空间的微计算机断层扫描分析

Micro-computed tomography analysis of post space preparation in root canals filled with carrier-based thermoplasticized gutta-percha.

作者信息

Schroeder A A, Ford N L, Coil J M

机构信息

Division of Endodontics, University of British Columbia, Vancouver, BC, Canada.

Centre for High-Throughput Phenogenomics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, BC, Canada.

出版信息

Int Endod J. 2017 Mar;50(3):293-302. doi: 10.1111/iej.12618. Epub 2016 Mar 6.

Abstract

AIM

To determine whether post space preparation deviated from the root canal preparation in canals filled with Thermafil, GuttaCore or warm vertically compacted gutta-percha.

METHODOLOGY

Forty-two extracted human permanent maxillary lateral incisors were decoronated, and their root canals instrumented using a standardized protocol. Samples were divided into three groups and filled with Thermafil (Dentsply Tulsa Dental Specialties, Johnson City, TN, USA), GuttaCore (Dentsply Tulsa Dental Specialties) or warm vertically compacted gutta-percha, before post space preparation was performed with a GT Post drill (Dentsply Tulsa Dental Specialties). Teeth were scanned using micro-computed tomography after root filling and again after post space preparation. Scans were examined for number of samples with post space deviation, linear deviation of post space preparation and minimum root thickness before and after post space preparation. Parametric data were analysed with one-way analysis of variance (anova) or one-tailed paired Student's t-tests, whilst nonparametric data were analysed with Fisher's exact test.

RESULTS

Deviation occurred in eight of forty-two teeth (19%), seven of fourteen from the Thermafil group (50%), one of fourteen from the GuttaCore group (7%), and none from the gutta-percha group. Deviation occurred significantly more often in the Thermafil group than in each of the other two groups (P < 0.05). Linear deviation of post space preparation was greater in the Thermafil group than in both of the other groups and was significantly greater than that of the gutta-percha group (P < 0.05). Minimum root thickness before post space preparation was significantly greater than it was after post space preparation for all groups (P < 0.01).

CONCLUSIONS

The differences between the Thermafil, GuttaCore and gutta-percha groups in the number of samples with post space deviation and in linear deviation of post space preparation were associated with the presence or absence of a carrier as well as the different carrier materials.

摘要

目的

确定在使用Thermafil、GuttaCore或热垂直加压牙胶充填的根管中,桩道预备是否偏离根管预备。

方法

42颗拔除的人类上颌恒侧切牙去除冠部,采用标准化方案进行根管预备。样本分为三组,分别用Thermafil(美国田纳西州约翰逊城登士柏 Tulsa牙科专业公司)、GuttaCore(登士柏 Tulsa牙科专业公司)或热垂直加压牙胶充填,然后用GT桩钻(登士柏 Tulsa牙科专业公司)进行桩道预备。根管充填后及桩道预备后分别使用微型计算机断层扫描对牙齿进行扫描。检查扫描结果,统计桩道预备出现偏差的样本数量、桩道预备的线性偏差以及桩道预备前后的最小牙根厚度。参数数据采用单因素方差分析(anova)或单尾配对学生t检验进行分析,非参数数据采用Fisher精确检验进行分析。

结果

42颗牙齿中有8颗出现偏差(19%),Thermafil组14颗中有7颗(50%),GuttaCore组14颗中有1颗(7%),牙胶组无偏差。Thermafil组出现偏差的频率显著高于其他两组(P < 0.05)。Thermafil组桩道预备的线性偏差大于其他两组,且显著大于牙胶组(P < 0.05)。所有组桩道预备前的最小牙根厚度均显著大于桩道预备后(P < 0.01)。

结论

Thermafil组、GuttaCore组和牙胶组在桩道预备出现偏差的样本数量及桩道预备的线性偏差方面的差异与是否存在载体以及载体材料不同有关。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验