The role of radiofrequency energy (RFE) devices has been minimally studied in hip arthroscopy. The purpose of this study was to determine the role of RFE devices in hip arthroscopy through a systematic review of the literature. We searched the PubMed database using the following Medical Subject Heading terms: hip arthroscopy, hip radiofrequency, thermal capsulorrhaphy, thermal chondroplasty and radiofrequency debridement. Two authors independently reviewed the literature and included articles based on predetermined inclusion criteria. We excluded review, technique and experimental articles. After title and abstract review, we selected 293 articles for full-text review. Ten articles met the inclusion and exclusion criteria. For the included articles, a total of 305 hips underwent arthroscopy with concomitant RFE treatment at a mean age of 25.7 years. Eight articles presented patient-reported outcome (PRO) instruments, one study did not report an outcome instrument but utilized an evaluation of postoperative range of motion (ROM) and 1 year magnetic resonance image (MRI) and computed tomography (CT) imaging. The remaining article measured only the ROM pre- and postoperatively. Only one of the articles reviewed reported complications. Current evidence on the safety and indications for use of RFE devices in hip arthroscopy is insufficient. The literature shows mixed results regarding its use in hip arthroscopy. Although the use of thermal energy is not without risk, if used judiciously and appropriate precautions are taken to avoid damage to adjacent tissues, those devices can be useful for the treatment of certain intra-articular hip pathologies arthroscopically.
射频能量(RFE)设备在髋关节镜检查中的作用研究极少。本研究的目的是通过系统回顾文献来确定RFE设备在髋关节镜检查中的作用。我们使用以下医学主题词在PubMed数据库中进行搜索:髋关节镜检查、髋关节射频、热囊缝合术、热软骨成形术和射频清创术。两位作者独立回顾文献,并根据预先确定的纳入标准纳入文章。我们排除了综述、技术和实验性文章。在标题和摘要审查后,我们选择了293篇文章进行全文审查。十篇文章符合纳入和排除标准。对于纳入的文章,共有305例髋关节接受了关节镜检查并同时进行了RFE治疗,平均年龄为25.7岁。八篇文章展示了患者报告结局(PRO)工具,一项研究未报告结局工具,但使用了术后活动范围(ROM)评估以及1年的磁共振成像(MRI)和计算机断层扫描(CT)成像。其余文章仅测量了术前和术后的ROM。所审查的文章中只有一篇报告了并发症。目前关于RFE设备在髋关节镜检查中使用的安全性和适应证的证据不足。文献显示其在髋关节镜检查中的使用结果不一。尽管使用热能并非没有风险,但如果谨慎使用并采取适当预防措施以避免损伤相邻组织,这些设备可有助于通过关节镜治疗某些髋关节内病变。