Suppr超能文献

使用带孔克氏针及带钢丝缠绕和加压的张力带系统治疗髌骨骨折

[TREATMENT OF PATELLAR FRACTURES USING Kirschner WITH HOLE AND TENSION BAND SYSTEM WITH WIRE WINDING AND PRESSURE].

作者信息

Li Chunjiang

出版信息

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2015 Dec;29(12):1466-8.

Abstract

OBJECTIVE

To investigate the effectiveness of internal fixation using Kirschner with hole and tensionband system with wire winding and pressure in the treatment of patellar fracture. Methods Between February 2008 andJanuary 2010, 39 patients with patellar fracture were treated using Kirschner with hole and tension band system with wire winding and pressure. The average age was 37 years (range, 18-65 years), including 23 males and 16 females. The left side was involved in 21 cases and the right side in 18 cases. The causes were falling injury in 21 cases, traffic accident injury in 11 cases, and striking injury in 7 cases. The injury to operation time was 5 hours to 6 days (mean, 3.5 days). Twelve cases had open fractures, and 19 cases had comminuted fractures.

RESULTS

All incisions healed by first intention, and no deep venous thrombosis of lower limbs formed. Thirty-nine patients followed up 12-21 months (mean, 14 months). There was no wire breaking during operation and after operation. X-ray film showed no re-fracture, fracture displacement, or needle displacement; fracture healed well, fracture line disappeared at 6-8 weeks (mean, 7.5 weeks) after operation. After 12 months, the internal fixation was removed; according to the Lysholm knee score standard, the results were excellent in 22 cases, good in 16 cases, fair in 1 case, and the excellent and good rate was 97.4%.

CONCLUSION

Internal fixation using Kirschner with hole and tension band system with wire winding and pressure has satisfactory effectiveness for the treatment of patellar fracture, with the following advantages: wire is not easy to break, the needle does not fall off, and the pressure strength is powerful.

摘要

目的

探讨带孔克氏针联合钢丝缠绕加压张力带系统内固定治疗髌骨骨折的疗效。方法 2008年2月至2010年1月,采用带孔克氏针联合钢丝缠绕加压张力带系统治疗39例髌骨骨折患者。平均年龄37岁(范围18 - 65岁),其中男性23例,女性16例。左侧21例,右侧18例。致伤原因:摔伤21例,交通事故伤11例,打击伤7例。受伤至手术时间为5小时至6天(平均3.5天)。开放性骨折12例,粉碎性骨折19例。

结果

所有切口均一期愈合,未形成下肢深静脉血栓。39例患者随访12 - 21个月(平均14个月)。术中及术后均未出现钢丝断裂。X线片显示无再骨折、骨折移位或针移位;骨折愈合良好,术后6 - 8周(平均7.5周)骨折线消失。术后12个月取出内固定;根据Lysholm膝关节评分标准,结果为优22例,良16例,可1例,优良率为97.4%。

结论

带孔克氏针联合钢丝缠绕加压张力带系统内固定治疗髌骨骨折疗效满意,具有钢丝不易断裂、针不易脱落、加压力量强大等优点。