Suppr超能文献

洗必泰氟化物清漆对恒牙咬合面窝沟变形链球菌计数及激光荧光读数的影响:一项半口研究。

The effect of a chlorhexidine-fluoride varnish on mutans streptococci counts and laser fluorescence readings in occlusal fissures of permanent teeth: A split-mouth study.

作者信息

Lipták Lídia, Bársony Nóra, Twetman Svante, Madléna Melinda

出版信息

Quintessence Int. 2016;47(9):767-73. doi: 10.3290/j.qi.a36327.

Abstract

OBJECTIVE

To evaluate the effect of a new chlorhexidine-fluoride varnish on mutans streptococci (MS) counts and laser fluorescence (LF) readings in fissures of permanent molars.

METHOD AND MATERIALS

The study group consisted of 57 healthy schoolchildren (7 to 14 yrs) that volunteered after informed consent. A double-blind split-mouth design was employed and 87 pairs of non-cavitated permanent molars were randomly assigned to treatments with either chlorhexidine-fluoride varnish (CHX-F) or chlorhexidine-thymol varnish (CHX-T, Cervitec Plus) as active control. The varnishes were topically applied at baseline and every sixth week throughout the 24-week study period. Endpoints were MS counts (CRT test) and occlusal LF readings (DIAGNOdent pen) registered regularly during follow-up.

RESULTS

At baseline, > 50% of the occlusal fissures harbored high MS counts (≥ 105 CFU), but a significant decrease (P < .05) was found after treatment with both varnishes. After 24 weeks, less than 5% exhibited high counts. There were no significant differences between the varnishes at any time point. The mean LF values were similar in both treatment groups at baseline, but a significant reduction (P < .05) was scored in the CHX-F group after 12 and 24 weeks. A similar reduction was found also in the CHX-T group after 24 weeks. No adverse events were reported.

CONCLUSION

There were no significant differences between the CHX-F and CHX-T varnishes in terms of MS suppression after four applications over 24 weeks. Both varnishes also reduced the LF readings significantly compared with baseline, but further long-term studies are needed to confirm a caries-preventive effect.

摘要

目的

评估一种新型洗必泰 - 氟化物清漆对恒磨牙窝沟中变形链球菌(MS)数量及激光荧光(LF)读数的影响。

方法与材料

研究组由57名健康学童(7至14岁)组成,他们在签署知情同意书后自愿参与。采用双盲、半口设计,87对未患龋的恒磨牙被随机分配接受洗必泰 - 氟化物清漆(CHX - F)或洗必泰 - 百里香酚清漆(CHX - T,Cervitec Plus)治疗作为阳性对照。在整个24周的研究期间内,清漆于基线时及每六周局部应用一次。观察终点为随访期间定期记录的MS数量(CRT试验)和咬合面LF读数(DIAGNOdent笔)。

结果

基线时,超过50%的咬合面窝沟中变形链球菌数量较高(≥105 CFU),但两种清漆治疗后均发现显著减少(P < 0.05)。24周后,只有不到5%的窝沟中变形链球菌数量较高。在任何时间点,两种清漆之间均无显著差异。两个治疗组在基线时的平均LF值相似,但CHX - F组在12周和24周后LF值显著降低(P < 0.05)。CHX - T组在24周后也有类似程度的降低。未报告不良事件。

结论

在24周内进行四次应用后,CHX - F和CHX - T清漆在抑制变形链球菌方面无显著差异。与基线相比,两种清漆均显著降低了LF读数,但需要进一步的长期研究来证实其防龋效果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验