Mir Altaf Ahmad, Goyal Bela, Datta Sudip Kumar, Ikkurthi Saidaiah, Pal Arnab
Department of Biochemistry, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
Department of Biochemistry, Postgraduate Institute of Medical Education and Research, Chandigarh, India; Department of Laboratory Medicine, All India Institute of Medical Sciences, New Delhi, India.
J Lab Physicians. 2016 Jul-Dec;8(2):71-6. doi: 10.4103/0974-2727.180785.
Free ionic calcium is the metabolically active component of total calcium (TCa) in blood. However, most laboratories report TCa levels that are dependent on serum albumin concentration. Hence, several formulae have evolved to calculate free calcium levels from TCa after adjustment for albumin. However, free calcium can directly be measured using direction selective electrodes rather than spectrophotometric methods used in autoanalyzers.
This study compares the levels of free calcium obtained by measurement by direct ion selective electrode (ISE) and the one calculated as a function of TCa by formulae.
A total of 254 serum samples submitted to clinical biochemistry laboratory of a tertiary care hospital were analyzed for total protein, albumin, and TCa by standard spectrophotometric methods and for free calcium by direct ISE. Three commonly used formulae viz. Orrell, Berry et al. and Payne et al. were used to calculate adjusted TCa. Calculated free calcium was obtained by taking 50% of these values.
A significant difference (P < 0.05) was observed between calculated free calcium by all the three formulae and measured free calcium estimated by direct ISE using paired t-test and Bland-Altman plots.
Formulae for predicting free calcium by estimating TCa and albumin lacks consistency in prediction and free calcium should be evaluated by direct measurement.
游离离子钙是血液中总钙(TCa)的代谢活性成分。然而,大多数实验室报告的总钙水平取决于血清白蛋白浓度。因此,已经出现了几种公式,用于在对白蛋白进行校正后从总钙计算游离钙水平。然而,游离钙可以使用直接选择性电极直接测量,而不是使用自动分析仪中的分光光度法。
本研究比较了通过直接离子选择性电极(ISE)测量获得的游离钙水平与通过公式作为总钙函数计算得出的游离钙水平。
将总共254份提交给一家三级护理医院临床生物化学实验室的血清样本,通过标准分光光度法分析总蛋白、白蛋白和总钙,并通过直接ISE分析游离钙。使用三种常用公式,即奥雷尔公式、贝里等人的公式和佩恩等人的公式来计算校正后的总钙。通过取这些值的50%获得计算得出的游离钙。
使用配对t检验和布兰德-奥特曼图,观察到所有三种公式计算得出的游离钙与通过直接ISE估计的测量游离钙之间存在显著差异(P < 0.05)。
通过估计总钙和白蛋白来预测游离钙的公式在预测方面缺乏一致性,游离钙应通过直接测量进行评估。