Nwankwo Chima D, Parrish Robin, Leasure Jeremi, McGann William A
Orthopedics. 2016 Nov 1;39(6):e1183-e1187. doi: 10.3928/01477447-20160808-03. Epub 2016 Aug 10.
Femur fractures occur during broaching and impaction of the implant during hip arthroplasty. Prophylactic cerclage of the proximal femur with braided cable and steel wire has been shown to decrease hoop stresses and has been posited as a way to decrease the incidence of intraoperative fracture. In this biomechanical study, the authors investigated the strain across the proximal femur during broaching after the application of stainless steel wire, comparing it with that for braided polyblend suture. Nine femur models were prepared, and strain gauges were applied to each of 3 groups. The control group received no cerclage, the second group received a double loop of suture, and the third group received a single loop of steel wire. A broach was firmly seated in each femur and sequentially increasing axial loads were applied at 1000 N, 2000 N, 3000 N, 4000 N, 5000 N, and 6000 N and to failure. Strain at all loads was lower in both cerclage groups than in the control group. Strain was 28.6%±12.4% lower in the suture group than in the control group (P=.0003). Strain was 30.8%±10.7% lower in the steel wire group than in the control group (P=.0011). There was no statistically significant difference between suture cerclage and steel wire cerclage (P=.7367). When used for prophylactic cerclage of the proximal femur, braided polyblend suture increases hoop stress resistance, decreases strain, and may play a clinically useful role in decreasing intraoperative proximal femur fractures during hip arthroplasty. [Orthopedics. 2016; 39(6):e1183-e1187.].
股骨骨折发生于髋关节置换术中植入物扩髓和嵌压过程。已证实使用编织缆线和钢丝对股骨近端进行预防性环扎可降低环向应力,并被认为是降低术中骨折发生率的一种方法。在这项生物力学研究中,作者研究了应用不锈钢丝后扩髓过程中股骨近端的应变情况,并与编织聚酯混合缝线进行比较。制备了9个股骨模型,应变片分别应用于3组中的每组。对照组不进行环扎,第二组接受双环缝线,第三组接受单环钢丝。将一个扩髓器牢固地植入每个股骨,并依次施加1000 N、2000 N、3000 N、4000 N、5000 N和6000 N的轴向载荷直至失效。两个环扎组在所有载荷下的应变均低于对照组。缝线组的应变比对照组低28.6%±12.4%(P = 0.0003)。钢丝组的应变比对照组低30.8%±10.7%(P = 0.0011)。缝线环扎和钢丝环扎之间无统计学显著差异(P = 0.7367)。当用于股骨近端的预防性环扎时,编织聚酯混合缝线可提高抗环向应力能力,降低应变,并可能在减少髋关节置换术中股骨近端术中骨折方面发挥临床有用作用。[《骨科》。2016;39(6):e1183 - e1187。]