Suppr超能文献

《康纳斯连续操作测验第二版在精神分裂症中的相对及绝对信度》

Relative and Absolute Reliabilities of the Conners' Continuous Performance Test II in Schizophrenia.

作者信息

Lee Posen, Lin Hung-Yu, Liu Chin-Hsuan, Lu Wen-Shian, Hsieh Ching-Lin

机构信息

Department of Occupational Therapy, I-Shou University, Kaohsiung, Taiwan.

Department of Occupational Therapy, Asia University, Taichung, Taiwan.

出版信息

Arch Clin Neuropsychol. 2016 Nov 22;31(7):769-779. doi: 10.1093/arclin/acw037.

Abstract

OBJECTIVE

The Conners' Continuous Performance Test II (CCPT-II) is one of the most commonly used tests of sustained attention in schizophrenia. To manage and monitor sustained attention deficits in schizophrenia, clinicians have to reliably assess the degree of attention impairment. The purpose of our study was to determine the relative and absolute reliability of the CCPT-II in schizophrenia.

METHOD

The final sample was a total of 108 patients with schizophrenia. The primary measures in this study were the CCPT-II and the Clinical Global Impression-Severity (CGI-S). The CCPT-II was administered twice, 1 month apart, by a specially trained occupational therapist. We assessed two types of reliability: relative and absolute reliability. Relative reliability was determined with the intra-class correlation coefficient (ICC). Absolute reliability was quantified with standard error of measurement (SEM), minimal detectable change (MDC), and Bland-Altman's 95% limits of agreement (LOA).

RESULTS

The ICCs for the five CCPT-II indexes (Omissions, Commissions, Hit RT, Hit RT Std Error, and Variability) ranged from 0.66 to 0.79. The MDCs (MDC%) of the five indices were 13.53 (156.78), 10.67 (47.85), 122.10 (34.16), 8.15 (106.82), and 25.81 (162.63), respectively.

CONCLUSIONS

According to the results, the CCPT-II has limited reliability in monitoring the sustained attention function of patients with schizophrenia. Our results can be used as a reference for the measurement error of CCPT-II to help clinicians and researchers determine the true change between successive assessments of patients with schizophrenia.

摘要

目的

康纳斯连续作业测试第二版(CCPT-II)是精神分裂症中最常用的持续性注意力测试之一。为了管理和监测精神分裂症患者的持续性注意力缺陷,临床医生必须可靠地评估注意力损害程度。我们研究的目的是确定CCPT-II在精神分裂症中的相对可靠性和绝对可靠性。

方法

最终样本共108例精神分裂症患者。本研究的主要测量指标为CCPT-II和临床总体印象-严重程度(CGI-S)。CCPT-II由经过专门培训的职业治疗师进行两次施测,间隔1个月。我们评估了两种可靠性:相对可靠性和绝对可靠性。相对可靠性通过组内相关系数(ICC)确定。绝对可靠性通过测量标准误(SEM)、最小可检测变化(MDC)和布兰德-奥特曼95%一致性界限(LOA)进行量化。

结果

CCPT-II五个指标(遗漏、错误、命中反应时、命中反应时标准误和变异性)的ICC范围为0.66至0.79。五个指标的MDC(MDC%)分别为13.53(156.78)、10.67(47.85)、122.10(34.16)、8.15(106.82)和25.81(162.63)。

结论

根据研究结果,CCPT-II在监测精神分裂症患者持续性注意力功能方面的可靠性有限。我们的结果可作为CCPT-II测量误差的参考,以帮助临床医生和研究人员确定精神分裂症患者连续评估之间的真实变化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验