Pottackal Mathai Jijo, Mohammed Hasheem
All India Institute of Speech and Hearing, Manasagangothri, Mysore, India.
Gadag District Hospital, Malsamudra, Karnataka, India.
Eur Arch Otorhinolaryngol. 2017 Feb;274(2):671-677. doi: 10.1007/s00405-016-4282-0. Epub 2016 Aug 30.
To investigate the effect of compression time settings and presentation levels on speech perception in noise for elderly individuals with hearing loss. To compare aided speech perception performance in these individuals with age-matched normal hearing subjects. Twenty (normal hearing) participants within the age range of 60-68 years and 20 (mild-to-moderate sensorineural hearing loss) in the age range of 60-70 years were randomly recruited for the study. In the former group, SNR-50 was determined using phonetically balanced sentences that were mixed with speech-shaped noise presented at the most comfortable level. In the SNHL group, aided SNR-50 was determined at three different presentation levels (40, 60, and 80 dB HL) after fitting binaural hearing aids that had different compression time settings (fast and slow). In the SNHL group, slow compression time settings showed significantly better SNR-50 compared to fast release time. In addition, the mean of SNR-50 in the SNHL group was comparable to normal hearing participants while using a slow release time. A hearing aid with slow compression time settings led to significantly better speech perception in noise, compared to that of a hearing aid that had fast compression time settings.
研究压缩时间设置和声音呈现水平对老年听力损失患者噪声环境下言语感知的影响。比较这些患者与年龄匹配的听力正常受试者的助听言语感知表现。本研究随机招募了20名年龄在60 - 68岁的(听力正常)参与者和20名年龄在60 - 70岁的(轻度至中度感音神经性听力损失)参与者。在前一组中,使用与以最舒适水平呈现的言语形状噪声混合的语音平衡句子来确定SNR - 50。在感音神经性听力损失组中,在佩戴具有不同压缩时间设置(快速和慢速)的双耳助听器后,于三个不同的呈现水平(40、60和80 dB HL)下确定助听SNR - 50。在感音神经性听力损失组中,与快速释放时间相比,慢速压缩时间设置显示出显著更好的SNR - 50。此外,在使用慢速释放时间时,感音神经性听力损失组的SNR - 50均值与听力正常的参与者相当。与具有快速压缩时间设置的助听器相比,具有慢速压缩时间设置的助听器在噪声环境下能带来显著更好的言语感知。