Evaluation of dialysis adequacy in hemodialysis patients: A systematic review.

作者信息

Barzegar Hengameh, Moosazadeh Mahmoud, Jafari Hedayat, Esmaeili Ravanbakhsh

机构信息

School of Nursing and Midwifery, Student Research Committee, Mazandaran University of Medical Sciences, Sari, Iran.

Health Sciences Research Center, Mazandaran University of Medical Sciences, Sari, Iran.

出版信息

Urol J. 2016 Aug 25;13(4):2744-9.

Abstract

PURPOSE

Hemodialysis is the common kidney replacement therapy in Iran. Doing an adequate and effective dialysis can improve patients' quality of life and reduce kidney failure complications. Additionally, dialysis quality is an important factor in reducing mortality in patients with chronic kidney failure. This systematic review has investigated the adequacy of dialysis in studies done on hemodialysis patients of Iran.

MATERIALS AND METHODS

All articles related to the dialysis adequacy in hemodialysis patients in English and Farsi (contemporary Persian) were identified by searching the related keywords in various electronic databases. According to the inclusion criteria 21 studies were identified. The results were analyzed using Stata software version 11.

RESULTS

A number of 6677 patients had been enrolled in 21 studies that were chosen for this systematic review. Based on the random effects model, the overall dialysis adequacy (KT/V) (K: clearance of urea, T: duration of dialysis, V: distribution of urea) more than 1.2 and confidence interval were 36.3% and 46.2-26.4, respectively. Also, based on random effects model more than 65% urea reduction ratio in all studies was 28.8% and the confidence interval was 43.3-14.4.

CONCLUSION

KT/V and urea reduction ratio were much less desirable in hemodialysis patients and the dialysis quality was also undesirable. It seems that inadequate dialysis prescription, use of inappropriate filters, low pump speed (blood flow speed), and the short duration and few times of dialysis are the major causes of this inadequacy.&nbsp.

摘要

目的

血液透析是伊朗常见的肾脏替代疗法。进行充分有效的透析可改善患者生活质量并减少肾衰竭并发症。此外,透析质量是降低慢性肾衰竭患者死亡率的重要因素。本系统评价调查了伊朗血液透析患者相关研究中透析的充分性。

材料与方法

通过在各种电子数据库中搜索相关关键词,确定了所有用英文和波斯语(现代波斯语)撰写的与血液透析患者透析充分性相关的文章。根据纳入标准,确定了21项研究。使用Stata软件11版对结果进行分析。

结果

本系统评价所选的21项研究共纳入了6677例患者。基于随机效应模型,总体透析充分性(KT/V)(K:尿素清除率,T:透析时长,V:尿素分布容积)大于1.2,置信区间分别为36.3%和46.2 - 26.4。此外,基于随机效应模型,所有研究中尿素清除率大于65%的比例为28.8%,置信区间为43.3 - 14.4。

结论

血液透析患者的KT/V和尿素清除率远未达到理想水平,透析质量也不理想。透析处方不充分、使用不合适的滤器、泵速(血流速度)低以及透析时间短和次数少似乎是导致这种不充分的主要原因。