Langford Edward, Khwanda Ahmad, Langford Kate
Department of Cardiology, Princess Royal University Hospital, South London Healthcare Trust.
Women's Health Department, St Thomas' Hospital , London , UK.
Obstet Med. 2010 Jun;3(2):65-8. doi: 10.1258/om.2010.090064. Epub 2010 Jun 3.
Measurement of oxygen saturation on excercise, using a pulse oximeter, has been advocated in the assessment of women with shortness of breath in pregnancy. However, there is currently no standard protocol for this. The aims of this study were to determine the normal range for oxygen saturation at rest and on moderate exercise in healthy women from 24 weeks gestation and to evaluate a simple, widely applicable exercise protocol in which women walked at their own pace for 100 metres then up two flights of stairs. The protocol achieved 60-85% maximum predicted heart rate in 99% of women at a median gestation of 31(+3) weeks, with a wide range of Hb and BMI. There was a mean 0.3% fall in oxygen saturation on exertion but oxygen saturation did not fall below 95% in any of the women.
在评估孕期气短的女性时,有人主张使用脉搏血氧仪测量运动时的血氧饱和度。然而,目前尚无对此的标准方案。本研究的目的是确定妊娠24周起健康女性静息和适度运动时血氧饱和度的正常范围,并评估一种简单、广泛适用的运动方案,即女性以自己的速度行走100米,然后上两层楼梯。在中位妊娠31(+3)周时,该方案在99%的女性中达到了最大预测心率的60 - 85%,这些女性的血红蛋白和体重指数范围广泛。运动时血氧饱和度平均下降0.3%,但所有女性的血氧饱和度均未降至95%以下。