Suppr超能文献

使用有创性对比剂左心室造影、二维超声心动图和门控单光子发射计算机断层扫描获得的左心室射血分数值的比较。

Comparison of left ventricular ejection fraction values obtained using invasive contrast left ventriculography, two-dimensional echocardiography, and gated single-photon emission computed tomography.

作者信息

Garg Nadish, Dresser Thomas, Aggarwal Kul, Gupta Vishal, Mittal Mayank K, Alpert Martin A

机构信息

Division of Cardiovascular Medicine, University of Missouri, Columbia, MO, USA; The Harry S Truman Memorial Veterans Hospital, Columbia, MO, USA.

出版信息

SAGE Open Med. 2016 Jun 24;4:2050312116655940. doi: 10.1177/2050312116655940. eCollection 2016.

Abstract

OBJECTIVES

Left ventricular ejection fraction can be measured by a variety of invasive and non-invasive cardiac techniques. This study assesses the relation of three diagnostic modalities to each other in the measurement of left ventricular ejection fraction: invasive contrast left ventriculography, two-dimensional echocardiography, and quantitative gated single-photon emission computed tomography.

METHODS

Retrospective chart review was conducted on 58 patients hospitalized with chest pain, who underwent left ventricular ejection fraction evaluation using each of the aforementioned modalities within a 3-month period not interrupted by myocardial infarction or revascularization.

RESULTS

The mean left ventricular ejection fraction values were as follows: invasive contrast left ventriculography (0.44±0.15), two-dimensional echocardiography (0.46±0.13), and gated single-photon emission computed tomography (0.37±0.10). Correlations coefficients and associated p values were as follows: invasive contrast left ventriculography versus two-dimensional echocardiography (r=0.69, p<0.001), invasive contrast left ventriculography versus gated single-photon emission computed tomography (r=0.80, p<0.0001), and gated single-photon emission computed tomography versus two-dimensional echocardiography (r=0.69, p<0.001).

CONCLUSION

Our results indicate that strong positive correlations exist among the three techniques studied.

摘要

目的

左心室射血分数可通过多种有创和无创心脏技术进行测量。本研究评估了三种诊断方式在测量左心室射血分数时相互之间的关系:有创对比剂左心室造影、二维超声心动图和定量门控单光子发射计算机断层扫描。

方法

对58例因胸痛住院的患者进行回顾性病历审查,这些患者在3个月内未因心肌梗死或血运重建而中断,分别接受了上述每种方式的左心室射血分数评估。

结果

左心室射血分数的平均值如下:有创对比剂左心室造影(0.44±0.15)、二维超声心动图(0.46±0.13)和门控单光子发射计算机断层扫描(0.37±0.10)。相关系数及相关p值如下:有创对比剂左心室造影与二维超声心动图(r = 0.69,p < 0.001)、有创对比剂左心室造影与门控单光子发射计算机断层扫描(r = 0.80,p < 0.0001)、门控单光子发射计算机断层扫描与二维超声心动图(r = 0.69,p < 0.001)。

结论

我们的结果表明,所研究的三种技术之间存在强正相关。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2690/5006806/09e0567b07c5/10.1177_2050312116655940-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验