锝-3P-整合素配体(Tc-3P-RGD)单光子发射计算机断层扫描(SPECT)与计算机断层扫描(CT)在诊断孤立性肺结节中的准确性比较。

Comparison of the accuracy of Tc-3P-RGD SPECT and CT in diagnosing solitary pulmonary nodules.

作者信息

Zhang Haishan, Gao Shi, Chen Bin, Cheng Guanghui

机构信息

Department of Nuclear Medicine, China-Japan Union Hospital, Jilin University, Changchun, Jilin 130033, P.R. China.

Department of Radiotherapy, China-Japan Union Hospital, Jilin University, Changchun, Jilin 130033, P.R. China.

出版信息

Oncol Lett. 2016 Oct;12(4):2517-2523. doi: 10.3892/ol.2016.5030. Epub 2016 Aug 17.

Abstract

The aim of the present study was to compare technetium-99m-(polyethylene glycol-4)-(Arg-Gly-Asp) (99mTc-3P-RGD) single-photon emission computed tomography (SPECT) and computed tomography (CT) in the noninvasive differentiation of solitary pulmonary nodules (SPNs). The present study prospectively investigated a consecutive series of 24 patients with SPN, who were newly diagnosed using radiography between September 2012 and January 2014. All patients underwent 99mTc-3P-RGD SPECT and CT scans using a dual-head variable-angle γ-camera equipped with high-resolution collimators. A blinded panel of two thoracic radiologists for CT and three nuclear physicians for SPECT analyzed the images using a 5-grade scale. The SPECT images were also semi-quantitatively evaluated using tumor to non-tumor localization ratios (T/NT). The results were verified by pathological examination of the biopsy material obtained from each patient with SPN, and receiver operating characteristic (ROC) curves were generated from these results. The present results revealed that there were 17 malignant and 7 benign SPNs among the 24 patients with SPN. The mean size of the SPN was 2.1±0.6 cm. Sensitivity of visual analysis for SPECT and CT were 100.0 and 82.4%, respectively, and specificity was 71.4% for the two methods. When the T/NT SPECT semiquantitative analysis (ratio, 1.64) was used as a cut-off, the sensitivity and specificity of SPECT were 100.0 and 71.4%, respectively. The areas under the ROC curves were 0.840 for visual analysis of SPECT [95% confidence interval (CI), 0.600-1.000], 0.849 for semiquantitative analysis of SPECT (95% CI, 0.618-1.000) and 0.815 for CT (95% CI, 0.626-1.000). In conclusion, the present results suggest that 99mTc-3P-RGD SPECT is more accurate than CT in the detection of malignant SPN, and visual analysis appears to be sufficient for the characterization of SPN.

摘要

本研究的目的是比较锝-99m-(聚乙二醇-4)-(精氨酸-甘氨酸-天冬氨酸)(99mTc-3P-RGD)单光子发射计算机断层扫描(SPECT)和计算机断层扫描(CT)在孤立性肺结节(SPN)无创鉴别诊断中的应用。本研究前瞻性地调查了2012年9月至2014年1月期间连续收治的24例新发SPN患者,这些患者均经X线摄影新确诊。所有患者均使用配备高分辨率准直器的双头可变角度γ相机进行99mTc-3P-RGD SPECT和CT扫描。由两名胸部放射科医生组成的CT盲评小组和三名核医学医生组成的SPECT盲评小组采用5级评分法对图像进行分析。SPECT图像还使用肿瘤与非肿瘤定位比值(T/NT)进行半定量评估。通过对每位SPN患者获取的活检材料进行病理检查来验证结果,并根据这些结果绘制受试者工作特征(ROC)曲线。本研究结果显示,24例SPN患者中,有17例为恶性,7例为良性。SPN的平均大小为2.1±0.6 cm。SPECT和CT视觉分析的敏感性分别为100.0%和82.4%,两种方法的特异性均为71.4%。以T/NT SPECT半定量分析(比值为1.64)作为截断值时,SPECT的敏感性和特异性分别为100.0%和71.4%。SPECT视觉分析的ROC曲线下面积为0.840 [95%置信区间(CI),0.600 - 1.000],SPECT半定量分析为0.849(95% CI,0.618 - 1.000),CT为0.815(95% CI,0.626 - 1.000)。总之,本研究结果表明,99mTc-3P-RGD SPECT在检测恶性SPN方面比CT更准确,视觉分析似乎足以对SPN进行特征描述。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2384/5038481/05ce86b7f4d8/ol-12-04-2517-g00.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验