Suppr超能文献

Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals.

作者信息

Jibiri Nnamdi Norbert, Akintunde Tawakalitu Oluwatoyin, Dambele Musa Yusuf, Olowookere Christopher Jimoh

机构信息

Ajayi Crowther University, Faculty of Natural Sciences, Department of Physics, Oyo Town, Nigeria, Phone: +2348055336092 E-mail:

出版信息

Mol Imaging Radionucl Ther. 2016 Oct 5;25(3):114-120. doi: 10.4274/mirt.96158.

Abstract

OBJECTIVE

The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria.

METHODS

Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG) and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement.

RESULTS

The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP) without cannula and with cannula were 10.68 (720.2) and 13.82 (556.4) mSv per week (and per annum), respectively. It was determined that the left hand of the personnel received higher doses than their right hand.

CONCLUSION

The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99mTc-MDP in Nigerian institutions to prevent excessive doses to personnel.

摘要

相似文献

3
Extremity and eye lens dosimetry for medical staff performing vertebroplasty and kyphoplasty procedures.
J Radiol Prot. 2013 Sep;33(3):635-45. doi: 10.1088/0952-4746/33/3/635. Epub 2013 Jun 27.
5
Interventional radiologists: occupational radiation doses and risks.
Radiology. 1993 Jun;187(3):729-33. doi: 10.1148/radiology.187.3.8497622.
6
Occupational radiation monitoring at a large medical center in Japan.
Radiol Phys Technol. 2014 Jul;7(2):271-6. doi: 10.1007/s12194-014-0262-5. Epub 2014 Feb 26.
8
Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic X-ray control.
Br J Radiol. 1993 Oct;66(790):899-901. doi: 10.1259/0007-1285-66-790-899.
9
Evaluation of patient and staff doses during various CT fluoroscopy guided interventions.
Health Phys. 2003 Aug;85(2):165-73. doi: 10.1097/00004032-200308000-00005.
10
MEASUREMENT OF EXTREMITY DOSES OF NUCLEAR ENERGY WORKER BY USING RING DOSIMETER.
Radiat Prot Dosimetry. 2020 Jun 24;188(3):271-275. doi: 10.1093/rpd/ncz283.

本文引用的文献

2
Trends in the utilization of medical procedures that use ionizing radiation.
Health Phys. 2008 Nov;95(5):612-27. doi: 10.1097/01.HP.0000327659.42618.c1.
4
Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology.
Radiat Prot Dosimetry. 2006;118(3):325-30. doi: 10.1093/rpd/nci369. Epub 2006 Jan 26.
7
Staff dosimetry in interventional cardiology.
Radiat Prot Dosimetry. 2001;94(1-2):99-103. doi: 10.1093/oxfordjournals.rpd.a006490.
8
Staff dosimetry protocols in interventional radiology.
Radiat Prot Dosimetry. 2001;94(1-2):193-6. doi: 10.1093/oxfordjournals.rpd.a006471.