Murphy Thomas E, Prufert-Bebout Leslie E, Bebout Brad M
Exobiology Dept., NASA Ames Research Center, Moffett Field, CA, 94035.
Biotechnol Prog. 2016 Nov;32(6):1601-1608. doi: 10.1002/btpr.2394. Epub 2016 Nov 14.
The results of a numerical study on the simulation of pulse amplitude modulated (PAM) fluorometry within dense suspensions of photosynthetic microorganisms are presented. The Monte Carlo method was used to solve the radiative transfer equation in an algae-filled cuvette, taking into account absorption, anisotropic scattering, and fluorescence, as well as Fresnel reflections at interfaces. This method was used to simulate the transport of excitation and fluorescence light in a common laboratory fluorometer. In this fluorometer, detected fluorescence originates from a multitude of locations within the algal suspension, which can be exposed to very different fluence rates. The fluorescence-weighted fluence rate is reported, which is the local fluence rate of actinic light, averaged over all locations from which detected fluorescence originated. A methodology is reported for recovering the fluorescence-weighted fluence rate as a function of the transmittance of measuring light and actinic light through the sample, which are easily measured with common laboratory fluorometers. The fluorescence-weighted fluence rate can in turn be used as a correction factor for recovering intrinsic physiological parameters, such as the functional cross section of Photosystem II, from apparent (experimental) values. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:1601-1615, 2016.
本文给出了对光合微生物密集悬浮液中脉冲幅度调制(PAM)荧光测定法进行模拟的数值研究结果。采用蒙特卡罗方法求解充满藻类的比色皿中的辐射传输方程,该方程考虑了吸收、各向异性散射、荧光以及界面处的菲涅尔反射。此方法用于模拟普通实验室荧光计中激发光和荧光的传输。在该荧光计中,检测到的荧光源自藻类悬浮液内的多个位置,这些位置可能会受到非常不同的光通量率的照射。报告了荧光加权光通量率,它是光化光的局部光通量率,对检测到荧光的所有位置进行平均得到。本文还报告了一种方法,可根据测量光和光化光透过样品的透过率来恢复荧光加权光通量率,而这两个透过率可以用普通实验室荧光计轻松测量。荧光加权光通量率进而可作为校正因子,用于从表观(实验)值中恢复诸如光系统II的功能截面等内在生理参数。©2016美国化学工程师学会 生物技术进展,32:1601 - 1615,2016。