Ayar M K, Yildirim T
Oper Dent. 2017 Jan/Feb;42(1):53-61. doi: 10.2341/15-193-L. Epub 2016 Nov 1.
Literature regarding the influence of Er,Cr:YSGG laser pulse frequency with different output power levels on adhesion properties of adhesive resin to lased enamel is limited. Therefore, the aim of the present study was to evaluate the effects of laser pulse frequency (20, 35, and 50 Hz) at two different output power settings (3 and 6 W) of Er,Cr:YSGG on the microtensile bond strength (μTBS) of adhesive resin to enamel. Crowns of 35 intact bovine incisors were embedded into self-cure acrylic resin individually, and then flat enamel surfaces were prepared with 600-grit silicon carbide papers under water cooling. Teeth were divided randomly into seven groups. Enamel surfaces were irradiated with Er,Cr:YSGG laser operated at one of six output power-pulse frequency combinations (6 W20 Hz, 6 W-35 Hz, 6 W-50 Hz, 3 W-20 Hz, 3 W-35 Hz, and 3 W-50 Hz) in groups 1-6, respectively. Bur-treated surfaces served as a control in group 7. After surface treatments and bonding procedures, composite build-ups were done in three layers up to a height of 4 mm. Next, all bonded teeth were sectioned into the resin-enamel sticks to be tested in a μTBS testing machine. The μTBS data were analyzed with univariate analysis of variance under a general linear model with the factor 'tooth' added as a random effect to the design. Resin-enamel interfaces were evaluated with scanning electron microscopy (SEM). The μTBS to laser-irradiated enamel in group 1 (6 W-20 Hz) was significantly lower than those of bur-treated enamel (p<0.05). However, group 6 (3 W-50 Hz) showed significantly higher μTBS values than did bur-treated teeth (p<0.05). SEM evaluation revealed enormous morphological alterations of laser-irradiated specimens, such as extensive vertical and horizontal microcracks and gaps, with the exception of group 6. The bonding effectiveness of adhesive resin to laser-irradiated enamel was affected by the pulse frequency of the Er,Cr:YSGG laser. Although the parameters recommended by the manufacturer lowered μTBS, increasing the pulse rate may maintain optimum μTBS.
钇钪镓石榴石(Er,Cr:YSGG)激光脉冲频率对粘结树脂与激光照射牙釉质粘结性能影响的文献有限。因此,本研究的目的是评估在Er,Cr:YSGG两种不同输出功率设置(3W和6W)下,激光脉冲频率(20、35和50Hz)对粘结树脂与牙釉质微拉伸粘结强度(μTBS)的影响。将35颗完整的牛切牙冠分别嵌入自凝丙烯酸树脂中,然后在水冷条件下用600目碳化硅砂纸制备平坦的牙釉质表面。牙齿被随机分为七组。第1 - 6组的牙釉质表面分别用Er,Cr:YSGG激光以六种输出功率 - 脉冲频率组合之一(6W - 20Hz、6W - 35Hz、6W - 50Hz、3W - 20Hz、3W - 35Hz和3W - 50Hz)进行照射。第7组用牙钻处理的表面作为对照。在表面处理和粘结程序之后,分三层进行复合树脂堆积,高度达到4mm。接下来,将所有粘结的牙齿切成树脂 - 牙釉质棒,在μTBS测试机上进行测试。μTBS数据在一般线性模型下进行单因素方差分析,并将“牙齿”因素作为随机效应添加到设计中。用扫描电子显微镜(SEM)评估树脂 - 牙釉质界面。第1组(6W - 20Hz)中激光照射牙釉质处的μTBS显著低于牙钻处理的牙釉质处(p < 0.05)。然而,第6组(3W - 50Hz)的μTBS值显著高于牙钻处理的牙齿(p < 0.05)。SEM评估显示,除第6组外,激光照射标本有巨大的形态改变,如广泛的垂直和水平微裂纹及间隙。粘结树脂与激光照射牙釉质的粘结效果受Er,Cr:YSGG激光脉冲频率的影响。虽然制造商推荐的参数降低了μTBS,但增加脉冲频率可能会维持最佳的μTBS。