Suppr超能文献

原发性醛固酮增多症中的肾上腺静脉采血:当右侧肾上腺采血缺失时,采用多项回归模型检测醛固酮分泌的侧别化

Adrenal venous sampling in primary aldosteronism: multinomial regression modeling to detect aldosterone secretion lateralization when right adrenal sampling is missing.

作者信息

Durivage Camille, Blanchette Rémi, Soulez Gilles, Chagnon Miguel, Gilbert Patrick, Giroux Marie-France, Bourdeau Isabelle, Oliva Vincent L, Lacroix André, Therasse Eric

机构信息

aDepartment of Radiology, Centre hospitalier de l'Université de Montréal [CHUM] bCentre de recherche, CHUM [CRCHUM] cDepartment of Mathematics and Statistic, University of Montreal dDivision of Endocrinology, Department of Medicine, Centre hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada.

出版信息

J Hypertens. 2017 Feb;35(2):362-368. doi: 10.1097/HJH.0000000000001165.

Abstract

OBJECTIVE

Difficulty to recognize or canulate the right adrenal vein is the most frequent cause of adrenal venous sampling (AVS) failure. We aimed to assess multinomial regression modeling (MRM) of peripheral and left adrenal vein samplings to detect lateralization of aldosterone secretion when the right AVS is missing.

METHODS

Simultaneous bilateral AVS samplings were performed before (basal) and after intravenous cosyntropin injection in 188 consecutive patients between December 1989 and September 2015. Different reference standards for lateralization of aldosterone secretion were defined for basal and for postcosyntropin AVS and according to lateralization index cutoffs at least 2 and at least 4. MRMs were built to detect lateralization of aldosterone secretion according to these reference standards using only peripheral and left adrenal veins samplings (without the right AVS). Detection accuracy was assessed by the area under the receiver operating characteristic (AUROC) curves and detection sensitivities were reported for specificity at least 95%.

RESULTS

For basal AVS with lateralization index at least 2, AUROC were respectively 0.931 [95% confidence interval (CI) 0.894-0.968] and 0.922 (95% CI 0.882-0.962) for right and left lateralization of aldosterone secretion detection and MRM could detect respectively 65.5 and 62.7% of the right and left lateralization of aldosterone secretion. For AVS after cosyntropin with lateralization index at least 4, AUROC were respectively 0.964 (95% CI: 0.940-0.987) and 0.955 (95% CI: 0.927-0.983) for right and left lateralization of aldosterone secretion, and MRM could detect respectively 77.2 and 72.9% of the right and left lateralization of aldosterone secretion.

CONCLUSION

MRM can detect lateralization of aldosterone secretion without the right AVS in most patients and could eliminate the need for repeat AVS when right adrenal vein canulation is nonselective or impossible.

摘要

目的

难以识别或穿刺右肾上腺静脉是肾上腺静脉采血(AVS)失败的最常见原因。我们旨在评估外周和左肾上腺静脉采血的多项回归模型(MRM),以在缺少右AVS时检测醛固酮分泌的侧别。

方法

在1989年12月至2015年9月期间,对188例连续患者在静脉注射促肾上腺皮质激素前(基础状态)和注射后进行双侧同步AVS采血。针对基础状态和促肾上腺皮质激素注射后的AVS,根据醛固酮分泌侧别的不同参考标准以及侧别指数截断值至少为2和至少为4来定义。使用仅外周和左肾上腺静脉采血(不包括右AVS)构建MRM,以根据这些参考标准检测醛固酮分泌的侧别。通过受试者操作特征曲线下面积(AUROC)评估检测准确性,并报告特异性至少为95%时的检测敏感性。

结果

对于基础状态下侧别指数至少为2的AVS,检测醛固酮分泌右侧别和左侧别的AUROC分别为0.931[95%置信区间(CI)0.894 - 0.968]和0.922(95% CI 0.882 - 0.962),MRM分别能检测出醛固酮分泌右侧别和左侧别的65.5%和62.7%。对于促肾上腺皮质激素注射后侧别指数至少为4的AVS,检测醛固酮分泌右侧别和左侧别的AUROC分别为0.964(95% CI:0.940 - 0.987)和0.955(95% CI:0.927 - 0.983),MRM分别能检测出醛固酮分泌右侧别和左侧别的77.2%和72.9%。

结论

MRM能够在大多数患者中在缺少右AVS的情况下检测醛固酮分泌的侧别,并且当右肾上腺静脉穿刺无选择性或无法进行时,可避免重复AVS。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验