Zhang Xiaolin, Marchetti Christine, Lee Jessica, Sun Yan, Debanne Sara, Jiang Ying, Kern Jami, Harrod Mark, Benetz Beth Ann, Pearlman Eric, Szczotka-Flynn Loretta
Department of Ophthalmology & Visual Sciences and University Hospitals Eye Institute, University Hospitals Case Medical Center, Cleveland, OH, United States.
Department of Epidemiology & Biostatistics, Case Western Reserve University, Cleveland, OH, United States.
Cont Lens Anterior Eye. 2017 Feb;40(1):33-41. doi: 10.1016/j.clae.2016.11.006. Epub 2016 Nov 19.
To assess corneal epithelial microstructure via confocal microscopy and determine if cellular changes are associated with lens care solutions during daily wear of silicone hydrogel contact lenses.
Corneal in vivo confocal microscopy with the Nidek ConfoScan4 was performed at baseline and after 5 months of lotrafilcon A daily contact lens wear. Enrolled participants were randomized to use either a polyhexamethylene biguanide (PHMB) preserved multipurpose care solution (MPS) or a peroxide based solution system. Lens and storage case bioburden were assessed with aerobic culture methods. Univariate and multivariable analyses were done to evaluate the association between solution use, or solution-related clinical covariates, and morphologic differences (hyper-reflectivity) in the superficial epithelial cells and epithelial basal cell density.
Data on 139 participants were available for analysis of superficial epithelial cells while data on 92 participants were available for epithelial basal cell density. Five months after randomization to the solution groups, 33% of participants had visible hyper-reflective cells. More participants using MPS had ≥1 hyper-reflective cells compared to peroxide users at 5 months (44% vs. 22%; p=0.006). Similarly at 5 months, more participants with solution-induced corneal staining (SICS) had ≥1 hyper-reflective cells compared to non-SICS participants (57% vs. 29%; p=0.010). The adjusted odds ratios (ORs) for risk of presenting with hyper-reflective cells in MPS users or SICS participants was 2.7 (95% CI; 1.27-5.65) and 3.4 (95% CI; 1.29-8.97), respectively. Basal cell density decreased by over 350 cells/mm over time (about 6%) in participants who had substantial bioburden on their lenses or in their storage case.
The confocal microscope can detect epithelial cellular changes in vivo during contact lens wear. Hyper-reflective superficial epithelial cells are associated with a PHMB preserved solution and decreases in basal epithelial cell density may be associated with bacterial bioburden.
通过共聚焦显微镜评估角膜上皮微观结构,并确定在日常佩戴硅水凝胶隐形眼镜期间,细胞变化是否与隐形眼镜护理液有关。
使用尼德克ConfoScan4在基线时以及佩戴lotrafilcon A日抛隐形眼镜5个月后进行角膜活体共聚焦显微镜检查。入选的参与者被随机分配使用聚六亚甲基双胍(PHMB)保存的多功能护理液(MPS)或基于过氧化物的护理液系统。采用需氧培养方法评估镜片和储存盒的生物负荷。进行单变量和多变量分析,以评估护理液使用、或与护理液相关的临床协变量,与浅表上皮细胞形态学差异(高反射性)和上皮基底细胞密度之间的关联。
139名参与者的数据可用于分析浅表上皮细胞,92名参与者的数据可用于分析上皮基底细胞密度。随机分组至护理液组5个月后,33%的参与者有可见的高反射性细胞。与使用过氧化物护理液的参与者相比,使用MPS的参与者在5个月时有≥1个高反射性细胞的更多(44%对22%;p=0.006)。同样在5个月时,与无溶液诱导角膜染色(SICS)的参与者相比,有SICS的参与者有≥1个高反射性细胞的更多(57%对29%;p=0.010)。MPS使用者或SICS参与者出现高反射性细胞风险的调整比值比(OR)分别为2.7(95%CI;1.27-5.65)和3.4(95%CI;1.29-8.97)。在镜片或储存盒中有大量生物负荷的参与者中,随着时间推移,基底细胞密度下降超过350个细胞/mm²(约6%)。
共聚焦显微镜可在隐形眼镜佩戴期间体内检测上皮细胞变化。高反射性浅表上皮细胞与PHMB保存的护理液有关,基底上皮细胞密度降低可能与细菌生物负荷有关。