Suppr超能文献

医生改良的C3型覆膜支架移植物作为治疗肾旁吻合口旁动脉瘤的首选解决方案。

Physician-Modified C3 Excluder Endograft as the Preferred Solution to Treat a Juxtarenal Para-Anastomotic Aneurysm.

作者信息

Couture Thibault, Coscas Raphaël, Lamas Henri, Mlynski Amélie, Javerliat Isabelle, Goeau-Brissonniere Olivier, Coggia Marc

机构信息

Department of Vascular Surgery, Ambroise Paré University Hospital, Assistance Publique - Hôpitaux de Paris, Boulogne-Billancourt, France; Faculté de Médecine Paris-Ile-de-France Ouest, UFR des sciences de la santé Simone Veil, Université Versailles Saint-Quentin en Yvelines, Montigny-le-Bretonneux, France.

Department of Vascular Surgery, Ambroise Paré University Hospital, Assistance Publique - Hôpitaux de Paris, Boulogne-Billancourt, France; Faculté de Médecine Paris-Ile-de-France Ouest, UFR des sciences de la santé Simone Veil, Université Versailles Saint-Quentin en Yvelines, Montigny-le-Bretonneux, France; UMR 1018, Inserm-Paris11 - CESP, Versailles Saint-Quentin-en-Yvelines University, Paris-Saclay University, Paul Brousse Hospital, Villejuif, France.

出版信息

Ann Vasc Surg. 2017 Feb;39:287.e1-287.e5. doi: 10.1016/j.avsg.2016.08.014. Epub 2016 Nov 24.

Abstract

Feasibility and early satisfactory results of physician-modified endografts have been reported. Most reports described the use of Cook Dacron aortic endografts (Cook Medical, Inc., Bloomington, IN). However, in some specific anatomic features (short aortic length, narrow aorta), the use of this device may not be appropriate.We here report a case of juxtarenal aortic aneurysm proximal to a former aortobifemoral graft in a high surgical risk patient. Due to a narrow proximal neck and a short aortic length, a physician-modified Gore C3 Excluder device (W. L. Gore & Associates, Inc., Flagstaff, AR) incorporating a fenestration for a large accessory renal artery was implanted. At 6-month follow-up, the aneurysm remains excluded and computed tomography scan demonstrates patent renal vessels.Surgeon-modified Gore C3 Excluder device implantation is feasible. Because of specific device characteristics (short main body, repositioning ability), it represents a valuable alternative in high-risk patients with juxtarenal aneurysms not amenable to other techniques.

摘要

已有关于医生改良型腔内移植物的可行性及早期良好效果的报道。大多数报道描述了使用库克涤纶主动脉腔内移植物(库克医疗公司,印第安纳州布卢明顿)。然而,在一些特定的解剖特征(主动脉长度短、主动脉狭窄)情况下,使用该装置可能并不合适。我们在此报告一例高危手术患者,其肾旁主动脉瘤位于既往主动脉双股动脉移植近端。由于近端颈部狭窄且主动脉长度短,植入了医生改良的戈尔C3 Excluder装置(W.L.戈尔联合公司,亚利桑那州弗拉格斯塔夫),该装置带有一个用于大的副肾动脉的开窗。在6个月的随访中,动脉瘤仍被隔绝,计算机断层扫描显示肾血管通畅。外科医生改良的戈尔C3 Excluder装置植入是可行的。由于该装置的特定特性(主体短、可重新定位能力),它是不适用于其他技术的高危肾旁动脉瘤患者的一种有价值的替代方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验